Manual
LCom
Page 81 of 158
•
TCP/IP port:
The TCP/IP port (TCP) for the MSSI SOAP service on the
LCom. Default: 8888.
Note:
The LCom must be restarted after changing the TCP/IP port for the
change to take effect.
•
Trace level:
The trace level for the MSSI protocol
– controls the trace output
of the MSSI protocol driver to the log file (usually: 0).
•
MSSI Station ID:
The unique MSSI station ID for this station.
•
Station name:
The name of the station (same as the station name that can be
set under “System”).
•
Manufacturer:
The manufacturer of the station (“Lufft”).
•
Measure interval:
The measure interval according to the MSSI standard.
Here: the polling interval for the UMB devices.
Limitation: the measure interval on the LCom is 1 minute and can not be
changed
.
•
“Storage” interval:
The data storage interval according to the MSSI standard
– in the case of LCom this is NOT the actual storage interval in the ring
memory on the SD card (the data is always stored at 1 minute intervals here)
but merely the interval at which the data is reported when reading stored
measurement values via MSSI.
•
Calculate min/max/avg/mod values for interval:
If the “data storage”
interval is greater than the measurement interval (1 minute) the
minimum/maximum/average/modal or sum of the measure values are
calculat
ed over the “storage” interval if this parameter is set. Otherwise, only
the last stored value for the “data storage” interval is reported.
•
Images directory:
The local directory/medium where the camera images are
to be stored. Possible locations are “SD Card” (“\Storage Card”), USB Stick
(“\Hard Disk”) or RAM (“\Temp”).
•
Number of images per camera:
The maximum number of camera images
which are to be stored per camera. Default: 500.
Note: This value should be selected so that sufficient memory space is
always available on the corresponding medium under all circumstances.
If measurement data are also stored on the medium (SD Card), the
Содержание 8511.EAK
Страница 1: ...Operating Manual LCom Lufft Communicator Order No 8511 EAK Version V2 18 1 11 2019 www lufft com ...
Страница 41: ...5 8 2 8 essSubSurfaceSensorTable The parameters for the subsurface temperature sensors are configured here ...
Страница 42: ...5 8 2 9 essSnapShotCameraTable The camera s is are configured here See Camera Support below ...
Страница 124: ...Manual LCom Page 124 of 158 The button show events opens a dialog showing the events stored on the device ...
Страница 133: ...Manual LCom Page 133 of 158 reactivated by disconnecting and reconnecting the USB stick wait time 3 seconds ...
Страница 153: ...Manual LCom Page 153 of 158 6 2 Connection Example ...