Page 102 of 158
5.13.1 Device Settings
•
Device-Type:
UMB or UMB+OPUS200. If Opus200 devices are connected in
addition to the UMB devices, the Opus200 devices are connected to the serial
port used for TLS Inselbus/Lokalbus, so these protocols may not be used
when Opus200 devices are attached.
•
Poll interval
: Interval at which the measurement data is requested from the
UMB devices (fix 1 minute).
•
Retries
: number of retries for the device communication.
•
Timeout
: Timeout for the UMB communication.
•
Max Class-ID:
maximum UMB class ID that is polled when reading the UMB
sensor network configuration
•
Reset BB after errors
: If no measurement can be obtained for the entire
configured (active) sensor after xx attempts, the baseboard is reset
– together
with the UMB devices.
•
Timeout/Timeout (long):
Timeouts for the Opus200 communication.
•
UMB PowerSaver active:
if this option is selected, the power supply for the
UMB sensor network can be automatically switched off (via GUB_1) if the
battery power is below a configured threshold.
Содержание 8511.EAK
Страница 1: ...Operating Manual LCom Lufft Communicator Order No 8511 EAK Version V2 18 1 11 2019 www lufft com ...
Страница 41: ...5 8 2 8 essSubSurfaceSensorTable The parameters for the subsurface temperature sensors are configured here ...
Страница 42: ...5 8 2 9 essSnapShotCameraTable The camera s is are configured here See Camera Support below ...
Страница 124: ...Manual LCom Page 124 of 158 The button show events opens a dialog showing the events stored on the device ...
Страница 133: ...Manual LCom Page 133 of 158 reactivated by disconnecting and reconnecting the USB stick wait time 3 seconds ...
Страница 153: ...Manual LCom Page 153 of 158 6 2 Connection Example ...