Manual
LCom
Page 145 of 158
6.1.2.2.1 Typ 129
– Ice Percentage (NIRS)
Wird verwendet mit ID 4 (Ergebnisse) in Antwortrichtung.
Position
Description
Value
Byte 1
Length
[4]
Byte 2
Channel
[1..254]
Byte 3
DE Type
[ 129 ]
Byte 4
TLS Manufacturer Code
[47] = Lufft
Byte 5
Ice percentage (%)
[0…100, 255]
Ice Percentage 0…100 %
255 = Error / no measurement possible
6.1.2.2.2 Type 131
– Water film height in 0.1mm
Position
Description
Value
Byte 1
Length
3
Byte 2
Channel
[1..254]
Byte 3
DE Type
[ 131 ]
Byte 4
Water film height
[0… 254]
6.1.2.2.3 Typ 132
– Road Condition (MicKS)
Position
Description
Value
Byte 1
Length
[3]
Byte 2
Channel
[1..254]
Byte 3
DE-Type
[ 132 ]
Byte 4
Road Condition
[0… 254]
value
0
Dry / not icy.
1
Damp
3
Wet