![Lufft 8511.EAK Скачать руководство пользователя страница 147](http://html1.mh-extra.com/html/lufft/8511-eak/8511-eak_operating-manual_1947031147.webp)
Manual
LCom
Page 147 of 158
Byte 5 + 2*n
Prognosis-Value n low byte
Byte 6 + 2*n
Prognosis-Value n high byte
6.1.2.2.6 Type 185
– Prognosis Road Condition
Position
Description
Value
Byte 1
Length
[5 + n ]
Byte 2
Channel
[1..254]
Byte 3
DE Type
[ 184 ]
Byte 4
TLS Manufacturer Code
[47] = Lufft
Byte 5
Number of Prognosis values (n)
n=0…36
Byte 6
Time Interval between values
[10..180] minutes
Byte 7
Prognosis-Value 1
Prognose-Value Road
Condition
…
coded as TLS Typ 70
Byte 6 + n
Prognosis-Value n
6.1.2.2.7 Typ 254: Boschung Alarm Status Code
Position
Description
Value
Byte 1
Length
[3]
Byte 2
Channel
[1..254]
Byte 3
DE-Type
[ 254 ]
Byte 4
AlarmCode
Coding of alarm stati in AlarmCode:
Alarm
1
Alarm
2
Alarm
3
Hex
-
-
-
00h
x
-
-
01h
x
x
-
02h
Содержание 8511.EAK
Страница 1: ...Operating Manual LCom Lufft Communicator Order No 8511 EAK Version V2 18 1 11 2019 www lufft com ...
Страница 41: ...5 8 2 8 essSubSurfaceSensorTable The parameters for the subsurface temperature sensors are configured here ...
Страница 42: ...5 8 2 9 essSnapShotCameraTable The camera s is are configured here See Camera Support below ...
Страница 124: ...Manual LCom Page 124 of 158 The button show events opens a dialog showing the events stored on the device ...
Страница 133: ...Manual LCom Page 133 of 158 reactivated by disconnecting and reconnecting the USB stick wait time 3 seconds ...
Страница 153: ...Manual LCom Page 153 of 158 6 2 Connection Example ...