PAR
Name / SUB xxx: Name
Default setting
Setting range
Address
SUB
044
: User-def fault 2
Not connected [0]
Selection list
0x2631:044
SUB
045
: PID off
Not connected [0]
Selection list
0x2631:045
SUB
046
: PID output=0
Not connected [0]
Selection list
0x2631:046
SUB
047
: PID-I inhibited
Not connected [0]
Selection list
0x2631:047
SUB
048
: PID-Inf ramp on
TRUE [1]
Selection list
0x2631:048
SUB
049
: Release brake
Not connected [0]
Selection list
0x2631:049
PAR 410
DigIn HW config.
SUB
002
: DigIn HW mode
Digital Input [0]
Selection list
0x2630:002
PAR 411
DI inversion
SUB
001
: DI1 inversion
Not inverted [0]
Selection list
0x2632:001
SUB
002
: DI2 inversion
Not inverted [0]
Selection list
0x2632:002
SUB
003
: DI3 inversion
Not inverted [0]
Selection list
0x2632:003
SUB
004
: DI4 inversion
Not inverted [0]
Selection list
0x2632:004
SUB
005
: DI5 inversion
Not inverted [0]
Selection list
0x2632:005
PAR 412
Freq. threshold
0.0 Hz
0.0 ... 599.0 Hz
0x4005
PAR 413
MOP startmod
Last value [0]
Selection list
0x4003
PAR 414
MOP starting value
SUB
001
: MOP starting freq
0.0 Hz
0.0 ... 599.0 Hz
0x4004:001
SUB
002
: MOP starting PID
0.00 PUnit
-300.00 ... 300.00 PUnit
0x4004:002
SUB
003
: MOP starting torque 0.0 %
0.0 ... 1000.0 %
0x4004:003
PAR 420
Digital outputs
SUB
001
: Relay function
Ready for operation [51] Selection list
0x2634:001
SUB
002
: DO1 function
Release brake [115]
Selection list
0x2634:002
SUB
010
: NETWordOUT1.00
Ready for operation [51] Selection list
0x2634:010
SUB
011
: NETWordOUT1.01
Reversal of rot. dir. [69]
Selection list
0x2634:011
SUB
012
: NETWordOUT1.02
Running [50]
Selection list
0x2634:012
SUB
013
: NETWordOUT1.03
Error [56]
Selection list
0x2634:013
SUB
014
: NETWordOUT1.04
Safe Torque Off [55]
Selection list
0x2634:014
SUB
015
: NETWordOUT1.05
Quick stop [54]
Selection list
0x2634:015
SUB
016
: NETWordOUT1.06
Actual speed=0 [71]
Selection list
0x2634:016
SUB
017
: NETWordOUT1.07
Device warning [58]
Selection list
0x2634:017
SUB
018
: NETWordOUT1.08
Release brake [115]
Selection list
0x2634:018
SUB
019
: NETWordOUT1.09
Current limit reached [78] Selection list
0x2634:019
SUB
020
: NETWordOUT1.10
Speed - setp=act [72]
Selection list
0x2634:020
SUB
021
: NETWordOUT1.11
Not connected [0]
Selection list
0x2634:021
SUB
022
: NETWordOUT1.12
Not connected [0]
Selection list
0x2634:022
SUB
023
: NETWordOUT1.13
Not connected [0]
Selection list
0x2634:023
SUB
024
: NETWordOUT1.14
Not connected [0]
Selection list
0x2634:024
SUB
025
: NETWordOUT1.15
Not connected [0]
Selection list
0x2634:025
PAR 421
DO inversion
SUB
001
: Relay inverted
Not inverted [0]
Selection list
0x2635:001
SUB
002
: DO1 inversion
Not inverted [0]
Selection list
0x2635:002
PAR 430
Analog input 1
SUB
001
: AI1 config.
0...10VDC [0]
Selection list
0x2636:001
SUB
002
: AI1 freq @ min
0.0 Hz
-1000.0 ... 1000.0 Hz
0x2636:002
SUB
003
: AI1 freq @ max
50.0 Hz
-1000.0 ... 1000.0 Hz
0x2636:003
SUB
004
: AI1 PID/Mom@min 0.00 PUnit/%
-300.00 ... 300.00 PUnit/%
0x2636:004
SUB
005
: AI1 PID/Mom@max 100.00 PUnit/%
-300.00 ... 300.00 PUnit/%
0x2636:005
SUB
006
: AI1 filter time
10 ms
0 ... 10000 ms
0x2636:006
SUB
007
: AI1 dead band
0.0 %
0.0 ... 100.0 %
0x2636:007
SUB
008
: AI1 monit.level
0.0 %
-100.0 ... 100.0 %
0x2636:008
SUB
009
: AI1 monit.action
Below level 1 [0]
Selection list
0x2636:009
SUB
010
: AI1 error resp.
Error [3]
Selection list
0x2636:010
* Default setting depending on the size.
Firmware-Version 01.01.01.00
Commissioning
Keypad parameter list
29
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.actechdrives.com - Email: [email protected]