10.8
Parameter change-over
For up to 32 freely selectable parameters, this function provides a change-over between four
sets with different parameter values.
DANGER!
Changed parameter settings are effective immediately.
The possible consequence is an unexpected response of the motor shaft while the inverter is
enabled.
▶
If possible, only carry out parameter changes while the controller is inhibited.
▶
Certain device commands or settings which might cause a critical state of the drive behav-
iour can generally only be carried out with controller inhibit.
Details
The parameter list is compiled in the same way as that of the "Favorites" via parameterisa-
tion. »EASY Starter« provides a user-friendly parameterisation dialog for this purpose.
Change-over to another value set can optionally be effected via corresponding device com-
mands and/or special functions/triggers:
4
Device commands for parameter change-over
^
148
4
Functions for parameter change-over
^
206
Parameter
Name / value range / [default setting]
Info
0x2022:011
(PAR 700/011)
Device commands: Save parameter set 1
(Device commands: Save par. set 1)
1 = save value set 1 of the "Parameter change-over" function.
•
When the device command has been executed successfully, the value
0 is shown.
0 Off / ready
Only status feedback.
1 On / start
Execute device command.
2 In progress
Only status feedback.
3 Action cancelled
4 No access
5 No access (controller inhibit)
0x2022:012
(PAR 700/012)
Device commands: Save parameter set 2
(Device commands: Save par. set 2)
1 = save value set 2 of the "Parameter change-over" function.
•
When the device command has been executed successfully, the value
0 is shown.
0 Off / ready
Only status feedback.
1 On / start
Execute device command.
2 In progress
Only status feedback.
3 Action cancelled
4 No access
5 No access (controller inhibit)
0x2022:013
(PAR 700/013)
Device commands: Save parameter set 3
(Device commands: Save par. set 3)
1 = save value set 3 of the "Parameter change-over" function.
•
When the device command has been executed successfully, the value
0 is shown.
0 Off / ready
Only status feedback.
1 On / start
Execute device command.
2 In progress
Only status feedback.
3 Action cancelled
4 No access
5 No access (controller inhibit)