11.3.3
Keypad setpoint source
The following function is used to select the keypad as setpoint source.
Preconditions
A setpoint change-over to the keypad is only effected if no setpoint source with a higher prior-
ity has been selected.
4
Priority of the setpoint sources
^
193
Parameter
Name / value range / [default setting]
Info
0x2631:016
(PAR 400/016)
Function assignment: Setpoint = Keypad
(Function list: Setpoint=Keypad)
•
For possible settings see description for
0x2631:001 (PAR 400/001)
.
^
188
Assignment of a trigger for the "Setpoint = Keypad" function.
Trigger = TRUE: the keypad is used as setpoint source (if the trigger
assigned has the highest setpoint priority).
Trigger = FALSE: no action / deactivate function again.
Notes:
•
The default keypad setpoint can be changed in keypad operating
mode via the arrow keys of the keypad.
00 Not connected
No trigger assigned (trigger is constantly FALSE).
11.3.4
Network setpoint source
Generally, the network can be optionally set as standard-setpoint source or, after correspond-
ing configuration via a bit of the mappable NETWordIN1 data word, can be activated as set-
point source.
Preconditions
A setpoint change-over to the network is only effected if no setpoint source with a higher pri-
ority has been selected.
4
Priority of the setpoint sources
^
193
Details
•
In order to generally set the network as standard setpoint source, go to
0x2860:001
(PAR 201/001)
and set the selection "5: Network".
•
If a bit of the mappable NETWordIN1 data word is to be used for activation, use
0x400E:001
(PAR 505/001)
to assign function "17: Setpoint = Network" to the corresponding bit of NET-
WordIN1.
4
General network settings
^
97
•
There is no specific function with a selectable trigger for a setpoint change-over to the net-
work.
Flexible I/O configuration
Setpoint change-over
Keypad setpoint source