Address
Name / Subindex: Name
Default setting
Setting range
D / F / A / M
0x2DA5
Diagnostics of analog input 2
001
: Value in percent
x.x %
- (Read only)
I16 / 10 / O / t
002
: Frequency value
x.x Hz
- (Read only)
I16 / 10 / O / t
003
: Process controller value
x.xx PUnit
- (Read only)
I16 / 100 / O / t
004
: Torque value
x.xx %
- (Read only)
I16 / 100 / O / t
016
: Status
-
- (Read only)
U16 / 1 / O / -
0x2DAA
Diagnostics of analog output 1
001
: Voltage
x.xx V
- (Read only)
U16 / 100 / O / t
002
: Current
x.xx mA
- (Read only)
U16 / 100 / O / t
0x2DAC
Keypad status
-
- (Read only)
U16 / 1 / O / t
0x2DAD
Internal hardware states
-
- (Read only)
U16 / 1 / O / -
0x2DDD
Actual frequency
x.x Hz
- (Read only)
I16 / 10 / O / t
0x2DDF
Axis information
001
: Rated current
x.xx A
- (Read only)
U16 / 100 / O / t
002
: Maximum current
x.xx A
- (Read only)
U16 / 100 / O / t
0x2EFF
001
: Bootloader activation key 1
0
0 ... 4294967295
U32 / 1 / C / -
002
: Bootloader activation key 2
0
0 ... 4294967295
U32 / 1 / C / -
003
: Bootloader activation key 3
0
0 ... 4294967295
U32 / 1 / C / -
0x4002
Speed display scaling
0.00
0.00 ... 650.00
U16 / 100 / P / -
0x4003
Motor potentiometer starting mode
Last value [0]
Selection list
U8 / 1 / P / -
0x4004
Motor potentiometer starting values
001
: Frequency
0.0 Hz
0.0 ... 599.0 Hz
U16 / 10 / P / -
002
: Process controller value
0.00 PUnit
-300.00 ... 300.00 PUnit
I16 / 100 / P / -
003
: Torque
0.0 %
0.0 ... 1000.0 %
U16 / 10 / P / -
0x4005
Frequency threshold
0.0 Hz
0.0 ... 599.0 Hz
U16 / 10 / P / -
0x4006
Load loss detection
001
: Threshold
0.0 %
0.0 ... 200.0 %
U16 / 10 / P / -
002
: Deceleration
0.0 s
0.0 ... 300.0 s
U16 / 10 / P / -
0x4008
Process input words
001
: NETWordIN1
0x0000
0x0000 ... 0xFFFF
U16 / 1 / KH / r
002
: NETWordIN2
0x0000
0x0000 ... 0xFFFF
U16 / 1 / KH / r
003
: NETWordIN3
0.0 %
0.0 ... 100.0 %
U16 / 10 / K / r
004
: NETWordIN4
0.0 %
0.0 ... 100.0 %
U16 / 10 / K / r
0x4009
Motor potentiometer values saved
001
: Frequency
x.x Hz
- (Read only)
U16 / 10 / CP / t
002
: Process controller value
x.xx PUnit
- (Read only)
U16 / 100 / CP / t
003
: Torque
x.x %
- (Read only)
U16 / 10 / CP / t
0x400A
Process output words
001
: NetWordOUT1
-
- (Read only)
U16 / 1 / H / t
002
: NetWordOUT2
-
- (Read only)
U16 / 1 / - / t
0x400B
Predefined process input data
001
: AC Drive control word
0x0000
0x0000 ... 0xFFFF
U16 / 1 / OKH / r
002
: LECOM control word (C135)
0x0000
0x0000 ... 0xFFFF
U16 / 1 / OKH / r
003
: Network setpoint frequency [0.1 Hz]
0.0 Hz
0.0 ... 599.0 Hz
U16 / 10 / OK / r
004
: Network setpoint speed [r/min]
0 rpm
0 ... 50000 rpm
U16 / 1 / OK / r
005
: Network setpoint frequency [0.01 Hz]
0.00 Hz
0.00 ... 599.00 Hz
U16 / 100 / OK / r
006
: Network speed setpoint
0.0 Hz
-599.0 ... 599.0 Hz
I16 / 10 / OK / r
007
: Network process controller setpoint
0.00 PUnit
-300.00 ... 300.00 PUnit
I16 / 100 / OK / r
008
: Network torque setpoint
0 Nm
-32768 ... 32767 Nm
I16 / 1 / OK / r