4.5
Keypad parameter list
For commissioning or diagnostics using the keypad, all parameters of the inverter that can
also be accessed by means of the keypad are listed in the following "Keypad parameter list".
•
The keypad parameter list is sorted in ascending order in compliance with the "Display
code" (PAR xxx).
•
In order to provide for quick access, all parameters of the inverter are divided into different
groups according to their function.
•
Group 0 contains the configurable "Favorites". In the default setting these are the most
common parameters for the solution of typical applications.
4
Favorites
^
162
•
By the hundreds digit of the PAR number (PAR Xxx) you can quickly see in which group the
parameter is to be found on the keypad:
Group/name
Parameter
Description
Group 1 - Diagnostics
PAR 1xx
Diagnostic/display parameters for displaying device-internal process fac-
tors, current actual values, and status messages.
4
Diagnostics
^
44
Group 2 - basic setting
PAR 2xx
Setting of the mains voltage, selection of the control and setpoint
source, starting and stopping performance, frequency limits and ramp
times.
4
Basic setting
^
66
Group 3 - Motor Control
PAR 3xx
Configuration of the motor and motor control
4
Motor control
^
77
Group 4 - I/O setting
PAR 4xx
Function assignment and configuration of the inputs and outputs
4
Flexible I/O configuration
^
186
Group 5 - network setting
PAR 5xx
Configuration of the network (if available)
4
Configuring the network
^
96
Group 6 - Process Controller
PAR 6xx
Configuration of the process controller
4
Configuring the process controller
^
138
Group 7 - Additional Functions
PAR 7xx
Parameterisable additional functions
4
Additional functions
^
144
A complete overview of all parameter indexes can be found in the annex in the
Parameter attribute list
.
^
229
How to read the keypad parameter list:
Column
Meaning
PAR
Parameter number on the keypad
Name / SUB xxx: name
Parameter name on the keypad
For SUB parameters: subindex and name
Default setting
Default setting of the parameter
Setting range
Possible setting range for the parameter. Format: minimum value ... maximum value [unit]
Address
Address of the parameter in the object directory. Format: index[:subindex]
Keypad parameter list (short overview of all parameters with display code)
PAR
Name / SUB xxx: Name
Default setting
Setting range
Address
PAR 100
Actual frequency
x.x Hz
- (Read only)
0x2DDD
PAR 101
Scaled actual value
x Units
- (Read only)
0x400D
PAR 102
Freq. setp. Hz
x.x Hz
- (Read only)
0x2B0E
PAR 103
Motor current %
x.x %
- (Read only)
0x6078
PAR 104
Act. motor current
x.x A
- (Read only)
0x2D88
PAR 105
DC bus
x V
- (Read only)
0x2D87
PAR 106
Motor voltage
x VAC
- (Read only)
0x2D89
PAR 107
Actual torque %
x.x %
- (Read only)
0x6077
* Default setting depending on the size.
Firmware-Version 01.01.01.00
Commissioning
Keypad parameter list
24