Parameter
Name / value range / [default setting]
Info
0x404C:001
(PAR 607/001)
Process controller influence: Acceleration time for
showing
(PID influence: Show time)
0.0 ... [5.0] ... 999.9 s
If the trigger assigned in
0x2631:048 (PAR 400/048)
of the "Activate
process controller influence ramp" function is TRUE, the influence of the
process controller is shown by means of a ramp with the acceleration
time set here.
0x404C:002
(PAR 607/002)
Process controller influence: Deceleration time for
masking out
(PID influence: Mask out time)
0.0 ... [5.0] ... 999.9 s
If the trigger assigned in
0x2631:048 (PAR 400/048)
of the "Activate
process controller influence ramp" function is FALSE, the influence of the
process controller is hidden via a ramp with the deceleration time set
here.