PAR
Name / SUB xxx: Name
Default setting
Setting range
Address
PAR 230
Opt.dev.det.
SUB
001
: Opt.det: start
Stop [0]
Selection list
0x2021:001
SUB
002
: Opt.det: time
5 s
0 ... 3600 s
0x2021:002
PAR 300
Motor ctrl mode
VFC open loop [6]
Selection list
0x2C00
PAR 301
Modes of op.
L-speed mode [-2]
Selection list
0x6060
PAR 302
V/f curve
Linear [0]
Selection list
0x2B00
PAR 303
V/f char. data
SUB
001
: Base voltage
230 V *
0 ... 5000 V
0x2B01:001
SUB
002
: Base frequency
50 Hz *
0 ... 599 Hz
0x2B01:002
PAR 304
Rotation mode
Forwards/backw. [1]
Selection list
0x283A
PAR 305
Switching frequency
8kHz var/opt/4 [21]
Selection list
0x2939
PAR 308
Motor overload
SUB
001
: Load at 60 sec
150 %
30 ... 200 %
0x2D4B:001
SUB
002
: Speed comp.
On [0]
Selection list
0x2D4B:002
SUB
003
: Error response
Error [3]
Selection list
0x2D4B:003
PAR 310
Motor Ø failure
SUB
001
: Ø error response
No response [0]
Selection list
0x2D45:001
SUB
002
: Ø error current
5.0 %
1.0 ... 10.0 %
0x2D45:002
SUB
003
: Ø error volt.
10.0 V
0.0 ... 100.0 V
0x2D45:003
PAR 315
Slip compens.
SUB
001
: Slip: gain
100.00 %
-200.00 ... 200.00 %
0x2B09:001
SUB
002
: Filter time
5 ms
1 ... 6000 ms
0x2B09:002
PAR 316
V/f boosts
SUB
001
: V/f boost: stat.
2.5 % *
0.0 ... 20.0 %
0x2B12:001
SUB
002
: V/f boost: dyn.
0.0 %
0.0 ... 20.0 %
0x2B12:002
PAR 317
Skip frequencies
SUB
001
: Frequency 1
0.0 Hz
0.0 ... 599.0 Hz
0x291F:001
SUB
002
: Bandwidth 1
0.0 Hz
0.0 ... 10.0 Hz
0x291F:002
SUB
003
: Frequency 2
0.0 Hz
0.0 ... 599.0 Hz
0x291F:003
SUB
004
: Bandwidth 2
0.0 Hz
0.0 ... 10.0 Hz
0x291F:004
SUB
005
: Frequency 3
0.0 Hz
0.0 ... 599.0 Hz
0x291F:005
SUB
006
: Bandwidth 3
0.0 Hz
0.0 ... 10.0 Hz
0x291F:006
PAR 318
Oscillation damping
SUB
001
: Oscillation: gain
20 %
-100 ... 100 %
0x2B0A:001
SUB
002
: Oscillation: time
5 ms
1 ... 600 ms
0x2B0A:002
PAR 319
Overr. point of field weak.
0.0 Hz
-599.0 ... 599.0 Hz
0x2B0C
PAR 320
Motor parameters
SUB
004
: Mot. speed
1450 rpm
50 ... 50000 rpm
0x2C01:004
SUB
005
: Mot. frequency
50.0 Hz
1.0 ... 1000.0 Hz
0x2C01:005
SUB
006
: Motor power
0.25 kW *
0.00 ... 655.35 kW
0x2C01:006
SUB
007
: Motor voltage
230 V *
0 ... 65535 V
0x2C01:007
SUB
008
: Mot. cosine phi
0.80
0.00 ... 1.00
0x2C01:008
PAR 322
Max. motor speed
6075 rpm
0 ... 480000 rpm
0x6080
PAR 323
Motor current
1.700 A *
0.001 ... 500.000 A
0x6075
PAR 324
Max current
200.0 %
0.0 ... 3000.0 %
0x6073
PAR 325
Motor torque
1.650 Nm *
0.001 ... 1000.000 Nm
0x6076
PAR 327
Axis commands
SUB
004
: Mot. ident.
0
0 ... 1
0x2822:004
SUB
005
: Motor assessment
0
0 ... 1
0x2822:005
PAR 332
Speed controller
SUB
001
: Speed contr.: gain
0.00193 Nm/rpm *
0.00000 ... 20000.00000 Nm/rpm
0x2900:001
SUB
002
: Speed contr.: time
80.0 ms *
1.0 ... 6000.0 ms
0x2900:002
* Default setting depending on the size.
Firmware-Version 01.01.01.00
Commissioning
Keypad parameter list
27
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.actechdrives.com - Email: [email protected]