Parameter
Name / value range / [default setting]
Info
79 Torque limit reached
TRUE if torque limit has been reached or exceeded. Otherwise FALSE.
80 Follower signal (4 … 20 mA) lost
TRUE if follower signal (4 … 20 mA) lower than 2 mA.
81 Error of analog input 1
TRUE if error detection for analog input 1 has been activated. Otherwise
FALSE.
The error detection function can be configured via the following param-
eters:
•
Monitoring threshold
0x2636:008 (PAR 430/008)
•
Monitoring condition
0x2636:009 (PAR 430/009)
•
Monitoring response
0x2636:010 (PAR 430/010)
4
Analog input 1
^
211
82 Error of analog input 2
TRUE if error detection for analog input 2 has been activated. Otherwise
FALSE.
The error detection function can be configured via the following param-
eters:
•
Monitoring threshold
0x2637:008 (PAR 431/008)
•
Monitoring condition
0x2637:009 (PAR 431/009)
•
Monitoring response
0x2637:010 (PAR 431/010)
4
Analog input 2
^
213
83 Load loss
TRUE if current motor current < threshold for load loss detection for at
least the delay for load loss detection. Otherwise FALSE.
•
Display of the present motor current in
0x6078 (PAR 103)
.
•
Setting Threshold in
0x4006:001 (PAR 710/001)
.
•
Setting Decelerationin
0x4006:002 (PAR 710/002)
.
4
Load loss detection
^
158
104 Local control active
TRUE if local keypad control ("LOC") active. Otherwise FALSE.
105 Remote control active
TRUE if remote control ("REM") via terminals, network, etc. active. Oth-
erwise FALSE.
106 Manual setpoint selection active
TRUE if manual setpoint selection ("MAN") via keypad active. Otherwise
FALSE.
•
Selection of the trigger for the "Setpoint = Keypad" function in
0x2631:016 (PAR 400/016)
.
107 Automatic setpoint selection active
TRUE if automatic setpoint selection ("AUTO") via terminals, network,
etc. active. Otherwise FALSE.
108 Parameter set 1 active
TRUE if parameter set 1 is loaded and active. Otherwise FALSE.
109 Parameter set 2 active
TRUE if parameter set 2 is loaded and active. Otherwise FALSE.
110 Parameter set 3 active
TRUE if parameter set 3 is loaded and active. Otherwise FALSE.
111 Parameter set 4 active
TRUE if parameter set 4 is loaded and active. Otherwise FALSE.
112 Loading of parameters successful
TRUE after any parameter set has been loaded. Otherwise FALSE.
113 Loading of parameters faulty
TRUE if any of the parameter sets could not be loaded. Otherwise FALSE.
114 Network control mode active
TRUE if the network requests the control. Otherwise FALSE.
115 Release holding brake
TRUE if the holding brake is released (or should be released). Otherwise
FALSE.
0x2635:001
(PAR 421/001)
Inversion of digital outputs: Relay
(DO inversion: Relay inverted)
Relay inversion
0 Not inverted
1 Inverted
0x4018:003
Relay: Cutout delay
0.000 ... [0.020] ... 65.535 s
Switch-off delay for the relay.
0x4018:004
Relay: Switch-on delay
0.000 ... [0.020] ... 65.535 s
Switch-on delay for the relay.
0x4018:005
Relay: Relay state
•
Read only
Display of the logic state of the relay.
0 FALSE
1 TRUE
0x4018:006
Relay: Trigger signal state
•
Read only
Display of the logic state of the trigger signal for the relay (without tak-
ing a ON/OFF delay set and inversion into consideration).
0 FALSE
1 TRUE
0x4018:007
Relay: Switching cycles
•
Read only
Display of the previous relay switching cycles.
Flexible I/O configuration
Configuration of digital outputs
Relay
217