10.9
Device profile CiA402
The CiA 402 device profile defines the functional behaviour of stepping motors, servo drives,
and frequency inverters. In order to be able to describe the different drive types, various oper-
ating modes and device parameters are specified in the device profile. Each operating mode
provides objects (e.g. for the setpoint speed, acceleration and deceleration) to generate the
desired drive behaviour.
Parameter
Name / value range / [default setting]
Info
0x6042
(PAR 781)
Target velocity
(Setp. speed vl)
-32768 ... [0] ... 32767 rpm
Setpoint speed (velocity mode).
0x6043
(PAR 782)
Velocity demand
(Speed interpol)
•
Read only: x rpm
Display of the interpolated setpoint speed (velocity mode).
0x6044
(PAR 783)
Velocity actual value
(Actual speed)
•
Read only: x rpm
Display of the actual speed (velocity mode).
0x6046:001
(PAR 784/001)
Velocity min max amount: Velocity min amount
(Min/max speed: VL min amount)
0 ... [0] ... 480000 rpm
Minimum speed (velocity mode).
0x6046:002
(PAR 784/002)
Velocity min max amount: Velocity max amount
(Min/max speed: VL max amount)
0 ... [480000] ... 480000 rpm
Maximum speed (velocity mode).
0x6048:001
(PAR 785/001)
Velocity acceleration: Delta speed
(Speed acc.: Delta speed)
0 ... [3000] ... 2147483647 rpm
Acceleration: speed interval
0x6048:002
(PAR 785/002)
Velocity acceleration: Delta time
(Speed acc.: Delta time)
0 ... [10] ... 65535 s
Acceleration: time interval
0x6049:001
(PAR 786/001)
Velocity deceleration: Delta speed
(Speed decel.: Delta speed)
0 ... [3000] ... 2147483647 rpm
Deceleration: speed interval
0x6049:002
(PAR 786/002)
Velocity deceleration: Delta time
(Speed decel.: Delta time)
0 ... [10] ... 65535 s
Deceleration: time interval
0x605A
Quick stop option code
Device status after exiting the quick stop ramp.
2 Quick stop ramp -> switch-on inhibited
Automatic change to the "Switch-on inhibited" device state.
6 Quick stop ramp -> quick stop active
The inverter remains in the "Quick stop active" device state.
0x605E
(PAR 791)
Fault reaction option code
(Resp. in the event of error)
Selection of the response to faults.
-2 DC braking
0 Coasting
The motor coasts down to standstill.
2 Quick Stop
0x6060
(PAR 301)
Modes of operation
(Modes of op.)
•
Setting can only be changed if controller inhibit is
active.
Selection of the operating mode.
-2 Lenze speed mode
0 Mode not changed or assigned
No operating mode (standstill).
2 Velocity mode
0x6061
(PAR 788)
Modes of operation display
(Modes of op. dis)
•
Read only
Display of the current operating mode.
-11 Lenze identification
-10 Lenze test mode
-2 Lenze speed mode
0 Mode not changed or assigned
No operating mode (standstill).
2 Velocity mode
0x6071
Target torque
-3276.8 ... [0.0] ... 3276.7 %
Setpoint torque
•
100 % ≡ Motor rated torque
0x6076 (PAR 325)
Additional functions
Device profile CiA402
177