Parameter
Name / value range / [default setting]
Info
0x232E:014
(PAR 583/014)
Modbus diagnostics of last RX data: Data byte 12
(RX data diagnostics: Last RxD byte24)
•
Read only
0x232E:015
(PAR 583/015)
Modbus diagnostics of last RX data: Data byte 13
(RX data diagnostics: Last RxD byte26)
•
Read only
0x232E:016
(PAR 583/016)
Modbus diagnostics of last RX data: Data byte 14
(RX data diagnostics: Last RxD byte28)
•
Read only
0x232E:017
(PAR 583/017)
Modbus diagnostics of last RX data: Data byte 15
(RX data diagnostics: Last RxD byte30)
•
Read only
0x232F:001
(PAR 585/001)
Modbus diagnostics of last TX data: Offset
(TX data diagnostics: TX data offset)
0 ... [0] ... 240
For purposes of diagnostics, the last message sent (max. 16 bytes) is
shown in 0x232F:1 ... 16. For longer messages, an offset can be specified
here, indicating from which byte of the message the display of the 16
bytes is to start.
0x232F:002
(PAR 585/002)
Modbus diagnostics of last TX data: Data byte 0
(TX data diagnostics: Last TxD byte0)
•
Read only
Display of the message sent last.
0x232F:003
(PAR 585/003)
Modbus diagnostics of last TX data: Data byte 1
(TX data diagnostics: Last TxD Byte1)
•
Read only
0x232F:004
(PAR 585/004)
Modbus diagnostics of last TX data: Data byte 2
(TX data diagnostics: Last TxD byte2)
•
Read only
0x232F:005
(PAR 585/005)
Modbus diagnostics of last TX data: Data byte 3
(TX data diagnostics: Last TxD byte3)
•
Read only
0x232F:006
(PAR 585/006)
Modbus diagnostics of last TX data: Data byte 4
(TX data diagnostics: Last TxD byte4)
•
Read only
0x232F:007
(PAR 585/007)
Modbus diagnostics of last TX data: Data byte 5
(TX data diagnostics: Last TxD byte5)
•
Read only
0x232F:008
(PAR 585/008)
Modbus diagnostics of last TX data: Data byte 6
(TX data diagnostics: Last TxD byte6)
•
Read only
0x232F:009
(PAR 585/009)
Modbus diagnostics of last TX data: Data byte 7
(TX data diagnostics: Last TxD byte7)
•
Read only
0x232F:010
(PAR 585/010)
Modbus diagnostics of last TX data: Data byte 8
(TX data diagnostics: Last TxD byte8)
•
Read only
0x232F:011
(PAR 585/011)
Modbus diagnostics of last TX data: Data byte 9
(TX data diagnostics: Last TxD byte9)
•
Read only
0x232F:012
(PAR 585/012)
Modbus diagnostics of last TX data: Data byte 10
(TX data diagnostics: Last TxD byte10)
•
Read only
0x232F:013
(PAR 585/013)
Modbus diagnostics of last TX data: Data byte 11
(TX data diagnostics: Last TxD byte11)
•
Read only
0x232F:014
(PAR 585/014)
Modbus diagnostics of last TX data: Data byte 12
(TX data diagnostics: Last TxD byte12)
•
Read only
0x232F:015
(PAR 585/015)
Modbus diagnostics of last TX data: Data byte 13
(TX data diagnostics: Last TxD byte13)
•
Read only
0x232F:016
(PAR 585/016)
Modbus diagnostics of last TX data: Data byte 14
(TX data diagnostics: Last TxD byte14)
•
Read only
Configuring the network
Modbus
Modbus diagnostics
130