Address
Name / Subindex: Name
Default setting
Setting range
D / F / A / M
009
: Monitoring condition
Input value < trigger
threshold [0]
Selection list
U8 / 1 / P / -
010
: Monitoring response
Error [3]
Selection list
U8 / 1 / P / -
0x2637
Analog input 2
001
: Input range
0 … 10 VDC [0]
Selection list
U8 / 1 / P / -
002
: Min value [Hz]
0.0 Hz
-1000.0 ... 1000.0 Hz
I16 / 10 / P / -
003
: Max value [Hz]
50.0 Hz
-1000.0 ... 1000.0 Hz
I16 / 10 / P / -
004
: Min value [Punit/%]
0.00 PUnit/%
-300.00 ... 300.00 PUnit/%
I16 / 100 / P / -
005
: Max value [Punit/%]
100.00 PUnit/%
-300.00 ... 300.00 PUnit/%
I16 / 100 / P / -
006
: Filter time
10 ms
0 ... 10000 ms
U16 / 1 / P / -
007
: Dead band
0.0 %
0.0 ... 100.0 %
U16 / 10 / P / -
008
: Monitoring threshold
0.0 %
-100.0 ... 100.0 %
I16 / 10 / P / -
009
: Monitoring condition
Input value < trigger
threshold [0]
Selection list
U8 / 1 / P / -
010
: Monitoring response
Error [3]
Selection list
U8 / 1 / P / -
0x2639
Analog output 1
001
: Output range
0 … 10 VDC [1]
Selection list
U8 / 1 / P / -
002
: Function
Output frequency [1]
Selection list
U8 / 1 / P / -
003
: Min signal value
0
-2147483648 ... 2147483647 I32 / 1 / P / -
004
: Max signal value
1000
-2147483648 ... 2147483647 I32 / 1 / P / -
0x2820
Holding brake control
001
: Operating mode
No braking function [2]
Selection list
U8 / 1 / P / r
002
: Engagement time
100 ms
0 ... 10000 ms
U16 / 1 / P / -
003
: Disengagement time
100 ms
0 ... 10000 ms
U16 / 1 / P / -
007
: Application threshold
0.2 Hz
0.0 ... 599.0 Hz
U16 / 10 / P / -
008
: Holding load
0.0 %
-500.0 ... 500.0 %
I16 / 10 / P / -
015
: Brake status
-
- (Read only)
U8 / 1 / - / -
0x2822
Axis commands
001
: Enable inverter
Controller inhibited [0]
Selection list
U8 / 1 / X / -
002
: Activate quick stop
0
0 ... 1
U8 / 1 / X / -
003
: Reset error
0
0 ... 1
U8 / 1 / X / -
004
: Motor identification
0
0 ... 1
U8 / 1 / X / -
005
: Motor assessment
0
0 ... 1
U8 / 1 / X / -
0x2823
001
: Last subindex
-
- (Read only)
U8 / 1 / - / -
002
: Status of last axis command
-
- (Read only)
U8 / 1 / - / -
0x2824
Control selection
Terminal mode (flexible
I/O configuration) [0]
Selection list
U8 / 1 / P / -
0x2826
Time-out for error response
6.0 s
0.0 ... 100.0 s
U16 / 10 / P / -
0x2827
Currently loaded parameter settings
-
- (Read only)
U8 / 1 / X / -
0x2829
Automatic storage in the memory module
Inhibit [0]
Selection list
U8 / 1 / P / -
0x282A
Status words
001
: Cause of controller inhibit
-
- (Read only)
U32 / 1 / O / -
002
: Cause of quick stop
-
- (Read only)
U16 / 1 / O / -
003
: Cause of stop
-
- (Read only)
U16 / 1 / O / -
004
: Extended status word
-
- (Read only)
U16 / 1 / O / t
005
: Device status
-
- (Read only)
U8 / 1 / O / t
0x282B
Inverter diagnostics
001
: Active control source
-
- (Read only)
U8 / 1 / O / t
002
: Active setpoint source
-
- (Read only)
U8 / 1 / O / t
003
: Keypad LCD status
-
- (Read only)
U8 / 1 / O / -
004
: Active drive mode
-
- (Read only)
U8 / 1 / O / t
005
: Most recently used control register
-
- (Read only)
U32 / 1 / OH / -
006
: Most recently used setpoint register
-
- (Read only)
U32 / 1 / OH / -
0x2831
Lenze status word
-
- (Read only)
U16 / 1 / O / t
* Default setting depending on the size.
Firmware-Version 01.01.01.00
Appendix
Parameter attribute list