12.2
Rated data
12.2.1
Connection to the 230 V system
Inverter
I51AE125B
I51AE137B
I51AE155B
I51AE175B
I51AE211B
I51AE215B
I51AE222B
Rated power
kW
0.25
0.37
0.55
0.75
1.1
1.5
2.2
Mains voltage range
1/N/PE AC 170 V ... 264 V, 45 Hz ... 65 Hz
Operating mode
S1
Max. surrounding air
temperature
°C
40
Switching frequency
kHz
4
Rated mains current
without mains choke A
4
5.7
7.6
10
14.3
16.7
22.5
with mains choke
A
3.6
4.8
7.1
8.8
11.9
13.9
16.9
Rated output current
A
1.7
2.4
3.2
4.2
6
7
9.6
Motor cable length
C2 residential area /
industrial premises
m
15
20
Weight
kg
0.75
0.95
1.35
12.2.2
Connection to the 400 V system
Inverter
I51AE137F
I51AE155F
I51AE175F
I51AE211F
I51AE215F
I51AE222F
Rated power
kW
0.37
0.55
0.75
1.1
1.5
2.2
Mains voltage range
3/N/PE AC 340 V ... 528 V, 45 Hz ... 65 Hz
Operating mode
S1
Max. surrounding air
temperature
°C
40
Switching frequency
kHz
4
Rated mains current
without mains choke A
1.8
2.5
3.3
4.4
5.4
7.8
with mains choke
A
1.4
2
2.6
3
3.7
5.3
Rated output current
A
1.3
1.8
2.4
3.2
3.9
5.6
Motor cable length
C2 residential area /
industrial premises
m
15
20
Weight
kg
0.75
0.95
1.35
Technical data
Rated data
Connection to the 230 V system
225