11.5
Activating DC braking manually
By means of the "DC braking" function, DC braking can be activated manually.
Preconditions
The current for DC braking must be set > 0 % so that the function can be executed.
Parameter
Name / value range / [default setting]
Info
0x2631:005
(PAR 400/005)
Function assignment: DC braking
(Function list: DC braking)
•
For possible settings see description for
0x2631:001 (PAR 400/001)
.
^
188
Assignment of a trigger for the "DC braking" function.
Trigger = TRUE: "DC braking" function is activated.
Trigger = FALSE: no action / deactivate function again.
4
DC braking
^
153
00 Not connected
No trigger assigned (trigger is constantly FALSE).
0x2B84:001
(PAR 704/001)
DC braking: Current
(DC braking: Current)
0.0 ... [0.0] ... 200.0 %
Braking current for DC braking.
•
100 % ≡ rated motor current
0x6075 (PAR 323)