Address
Name / Subindex: Name
Default setting
Setting range
D / F / A / M
0x400C
Predefined process output data
001
: AC Drive status word
-
- (Read only)
U16 / 1 / - / t
002
: LECOM status word (C150)
-
- (Read only)
U16 / 1 / - / t
003
: Actual frequency [0.1 Hz]
x.x Hz
- (Read only)
U16 / 10 / - / t
004
: Actual motor speed [r/min]
x rpm
- (Read only)
U16 / 1 / - / t
005
: Drive status
-
- (Read only)
U16 / 1 / - / t
006
: Actual frequency [0.01 Hz]
x.xx Hz
- (Read only)
U16 / 100 / - / t
0x400D
Scaled actual value
x Units
- (Read only)
I16 / 1 / O / t
0x400E
NETWordIN1 function assignment
001
: Bit 0
Not active [0]
Selection list
U8 / 1 / CP / -
002
: Bit 1
Not active [0]
Selection list
U8 / 1 / CP / -
003
: Bit 2
Quick stop [3]
Selection list
U8 / 1 / CP / -
004
: Bit 3
Forward run (CW) [8]
Selection list
U8 / 1 / CP / -
005
: Bit 4
Reversal [13]
Selection list
U8 / 1 / CP / -
006
: Bit 5
DC braking [5]
Selection list
U8 / 1 / CP / -
007
: Bit 6
Not active [0]
Selection list
U8 / 1 / CP / -
008
: Bit 7
Reset error [4]
Selection list
U8 / 1 / CP / -
009
: Bit 8
Preset val. selection bit 0
[18]
Selection list
U8 / 1 / CP / -
010
: Bit 9
Preset val. selection bit 1
[19]
Selection list
U8 / 1 / CP / -
011
: Bit 10
Not active [0]
Selection list
U8 / 1 / CP / -
012
: Bit 11
Not active [0]
Selection list
U8 / 1 / CP / -
013
: Bit 12
Not active [0]
Selection list
U8 / 1 / CP / -
014
: Bit 13
Not active [0]
Selection list
U8 / 1 / CP / -
015
: Bit 14
Not active [0]
Selection list
U8 / 1 / CP / -
016
: Bit 15
Not active [0]
Selection list
U8 / 1 / CP / -
0x4016
Digital output 1
003
: Cutout delay
0.020 s
0.000 ... 65.535 s
U16 / 1000 / P / -
004
: Switch-on delay
0.020 s
0.000 ... 65.535 s
U16 / 1000 / P / -
005
: Terminal state
-
- (Read only)
U8 / 1 / X / -
006
: Trigger signal state
-
- (Read only)
U8 / 1 / X / -
0x4018
Relay
003
: Cutout delay
0.020 s
0.000 ... 65.535 s
U16 / 1000 / P / -
004
: Switch-on delay
0.020 s
0.000 ... 65.535 s
U16 / 1000 / P / -
005
: Relay state
-
- (Read only)
U8 / 1 / X / -
006
: Trigger signal state
-
- (Read only)
U8 / 1 / X / -
007
: Switching cycles
-
- (Read only)
U32 / 1 / X / -
0x401F
Process controller diagnostics
001
: Current setpoint
x.xx PUnit
- (Read only)
I16 / 100 / O / t
002
: Current feedback
x.xx PUnit
- (Read only)
I16 / 100 / O / t
003
: Status
-
- (Read only)
U8 / 1 / O / t
0x4020
Process controller
001
: Operating mode
Inhibited [0]
Selection list
U8 / 1 / P / -
002
: Feedback source
Analog input 1 [1]
Selection list
U8 / 1 / P / -
003
: Closed-loop controlled speed range
100 %
0 ... 100 %
U16 / 1 / P / -
004
: Speed feedforward control source
Without speed
feedforward control [0]
Selection list
U8 / 1 / P / -
0x4021
Process controller speed operation
001
: Acceleration time
1.0 s
0.0 ... 3600.0 s
U16 / 10 / P / -
002
: Deceleration time
1.0 s
0.0 ... 3600.0 s
U16 / 10 / P / -
* Default setting depending on the size.
Firmware-Version 01.01.01.00
Appendix
Parameter attribute list
245