13.2
Parameter attribute list
The parameter attribute list in particular contains some information required for reading and
writing parameters via network.
•
The parameter attribute list contains all parameters of the inverter.
•
The parameter attribute list is sorted by addresses (index:subindex) in ascending order.
How to read the parameter attribute list:
Column
Meaning
Address
Address of the parameter in the object directory. Format: index[:subindex]
If available: display code (parameter designation on the keypad). Format: (PAR number)
Name
Parameter short text (display text)
Default setting
Default setting of the parameter
D / F / A / M
D = data type of the parameter:
I8
1 byte, with sign
I16
2 bytes with sign
I32
4 bytes with sign
I64
8 bytes with sign
U8
1 byte without sign
U16
2 bytes without sign
U32
4 bytes without sign
U64
8 bytes without sign
REAL32
4 bytes floating point
STRING[xx]
ASCII string (with character length xx)
OCTET[xx]
OCTET string (with xx bytes)
L_INDEX
4 bytes without sign. Is used specially for addressing Lenze parameters.
F = factor for data transmission via network, depending on the number of decimal positions.
•
The integer value read via network must be divided by the corresponding factor in order to receive the actual dis-
play value.
•
The actual setting value must be multiplied with the corresponding factor in order to receive the integer value to
be written via network.
1
No decimal positions
10
1 decimal position
100
2 decimal positions
1000
3 decimal positions
10000
4 decimal positions
A = attributes (combinations of several attributes also possible):
C
Writing is only possible if the controller is inhibited
E
Value is displayed as IP address on the keypad
H
Value is displayed as hexadecimal value on the keypad
K
Parameter is only shown on the keypad
P
Setting is saved in the memory module
X
Hidden parameter: only accessible if a password is set.
M = Mapping:
r
Receive mapping permissible
t
Transmit mapping permissible
rt
Receive and transmit mapping permissible
Parameter attribute list (short overview of all parameter indexes)
Address
Name / Subindex: Name
Default setting
Setting range
D / F / A / M
0x1000
Device type
-
- (Read only)
U32 / 1 / H / -
0x1001
Error register
-
- (Read only)
U8 / 1 / H / t
0x1005
COB-ID SYNC
0x00000080
0x00000000 ... 0xFFFFFFFF
U32 / 1 / PH / -
0x1006
Communication cyclic period
0 us
0 ... 65535000 us
U32 / 1 / P / -
0x1008
Manufacturer's device name
-
- (Read only)
STRING[50] / 1 / - / -
0x1009
Manufacturer hardware version
-
- (Read only)
STRING[50] / 1 / - / -
0x100A
Manufacturer software version
-
- (Read only)
STRING[50] / 1 / - / -
* Default setting depending on the size.
Firmware-Version 01.01.01.00
Appendix
Parameter attribute list
229
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.actechdrives.com - Email: [email protected]