Parameter
Name / value range / [default setting]
Info
0x283A
(PAR 304)
Limitation of rotation
(Rotation mode)
Optional restriction of the rotating direction.
0 Only forwards
The motor can only be traversed in forward direction, since the transfer
of negative frequency and process controller setpoints to the motor con-
trol is avoided.
•
This function takes effect after the "Reversal" function (
0x2631:013
(PAR 400/013)
).
•
Since this function only avoids negative setpoints, traversing in back-
ward direction is possible if the motor has been wired for this rotating
direction.
1 Forwards and backwards
The motor can be traversed in both directions.
0x2860:001
(PAR 201/001)
Standard setpoint sources: Frequency setpoint source
(Standard setpoint: Frequency setp.)
•
For possible settings see description for
0x2860:001 (PAR 201/001)
.
^
70
Selection of the standard setpoint source for speed mode.
•
The standard setpoint source is always active in speed mode if no set-
point change-over to another setpoint source via corresponding trig-
gers/functions is active.
4
Setpoint change-over
^
193
2 Analog input 1
The setpoint is specified analogously via X3/AI1.
4
Analog input 1
^
211
0x2911:001
(PAR 450/001)
Preset frequency values: Preset value 1
(Preset frequency values: Preset value 1)
0.0 ... [20.0] ... 599.0 Hz
Parameterisable frequency setpoints (preset values) for speed mode.
0x2911:002
(PAR 450/002)
Preset frequency values: Preset value 2
(Preset frequency values: Preset value 2)
0.0 ... [40.0] ... 599.0 Hz
0x2911:003
(PAR 450/003)
Preset frequency values: Preset value 3
(Preset frequency values: Preset value 3)
0.0 ... [50.0] ... 599.0 Hz
0x2915
(PAR 210)
Minimum frequency
(Min. frequency)
0.0 ... [0.0] ... 599.0 Hz
Lower limit value for all frequency setpoints.
0x2916
(PAR 211)
Maximum frequency
(Max. frequency)
0.0 ... [50.0] ... 599.0 Hz
Upper limit value for all frequency setpoints.
0x2917
(PAR 220)
Acceleration time 1
(Acceleration time 1)
0.0 ... [5.0] ... 3600.0 s
The acceleration time set refers to the acceleration from standstill to the
maximum frequency set. In the case of a lower setpoint selection, the
actual acceleration time is reduced accordingly.
0x2918
(PAR 221)
Deceleration time 1
(Deceleration time 1)
0.0 ... [5.0] ... 3600.0 s
The deceleration time set refers to the deceleration from the maximum
frequency set to standstill. In the case of a lower actual frequency, the
actual deceleration time is reduced accordingly.
0x291C
(PAR 225)
Quick stop deceleration time
(QSP dec. time)
0.0 ... [1.0] ... 3600.0 s
If the "Quick stop" function is activated, the motor is brought to a stand-
still within the deceleration time set here.
The deceleration time set refers to the deceleration from the maximum
frequency set to standstill. In the case of a lower actual frequency, the
actual deceleration time is reduced accordingly.
All possible basic settings are described in the "
Basic setting
" chapter.
^
66
Commissioning
Parameter setting
Basic inverter settings
19