6
OPERATION
70
OPTIFLEX 1300 C
www.krohne.com
01/2008 • 4000172301 - HB OPTIFLEX 1300 R02 en
Menu No. Step
Function
Function description
Selection list
Default
A.1.3
installation
Follow this procedure to
describe the process
connection.
1
tank height
The distance from the
tank connecting flange
face/thread stop down
to the tank bottom.
min-max: 0.165
…
60 m /
0.54
…
196.86 ft
4
2
type of process
connection
The installation on the
tank for the instrument.
socket, stillwell, nozzle
nozzle
3A
stillwell height
The height from the tank
connecting flange
face/thread stop to the
bottom of the stillwell.
min-max: 0
…
60 m /
0
…
196.86 ft
1.5 m /
4.92 ft
4A
stillwell diameter
The inner diameter of
the stillwell.
min-max:
0.2
…
1000 mm /
0.79
…
39.37 in
100 mm
/ 3.94 in
3B
nozzle height
The height from the tank
connecting flange
face/thread stop to the
bottom of the nozzle.
min-max: 0
…
60 m /
0
…
196.86 ft
0.1 m /
0.33 ft
4B
nozzle diameter
The inner diameter of
the nozzle.
min-max:
0.2
…
1000 mm /
0.79
…
39.37 in
100 mm
/ 3.94 in
5
settings summary
6
save / cancel
save, cancel
3