6
OPERATION
76
OPTIFLEX 1300 C
www.krohne.com
01/2008 • 4000172301 - HB OPTIFLEX 1300 R02 en
B.1.4
set output 2 This sets analogue output 2 to a
test value [mA] selected from a
list. Output will change to the
selected value, independent of
the measured value.
3.6, 4, 6, 8, 10, 12, 14, 16, 18, 20
or 22 mA
4 mA
B.1.5
internal
test
This initiates the hardware test.
The device displays the results.
read only
B.2
information
A summary of information
relating to the device
B.2.1
outputs
Analogue output settings. This
includes assigned functions, 4
…
20 mA scale settings,error
handling and HART
®
parameters.
read only
B.2.2
15 minute
log
A log of output values for the
last 15 minutes. A log is taken
every 10 seconds and displayed
on a graph.
read only
B.2.3
device
identificatio
n
This displays device order
no,CPLD-no, V-no, service no,
firmware 1 version, firmware 2
version, firmware 3 version and
Ex approval details.
read only
B.2.4
quick setup
summary
A summary of the parameters
entered in the quick setup
menu
read only
B.2.5
TAG
number
The TAG number can be seen
and updated here
?
TAGNO0123
4567890
B.2.6
Sensor
length
The distance from the flange
face/thread stop down to the
bottom end of the probe
(including counterweight for
cable versions). The factory set
value for probe length is
displayed. If probe length has
been modified, the new value is
shown.
read only (blocking
distance
…
60 m / 197 ft)
B.2.7
Probe type
The mechanical design of the
probe. The factory installed
probe type is displayed.
read only
B.2.8
counterwei
ght type
The mechanical design of a
cable probe's bottom end. The
device will not measure below
the top of the counterweight.
The factory-installed
counterweight type is
displayed.
read only
Temperatur
e
Temperature of the electronics
block.
read only
B.2.9
calculated
ε
r
value
dielectric constant [
ε
r
] is a
major parameter for TDR level
measurement devices. This
device is able to automatically
calculate and display here the
ε
r
of the top product.
read only
Menu No. Function
Function descritpion
Selection list
Default
HB_OPTIFLEX1300_EN_D4_080428.book Page 76 Tuesday, April 29, 2008 2:47 PM