6
OPERATION
100
OPTIFLEX 1300 C
www.krohne.com
01/2008 • 4000172301 - HB OPTIFLEX 1300 R02 en
6.4.12 How to decrease the length of probes
How to decrease the length of single rod probes
•
Measure the length of the rod from the flange facing.
•
Cut the rod to the correct length.
•
Go to Supervisor > Advanced setup > Installation > Probe length
Supervisor > Advanced setup > Installation > Probe length
Supervisor > Advanced setup > Installation > Probe length
Supervisor > Advanced setup > Installation > Probe length.
•
Type in the new value. Press
^
.
•
Press > and (Esc) at the same time to exit to the "save settings" window.
•
Select Save
Save
Save
Save and press
^
.
How to decrease the length of cable probes
•
Loosen the socket set screws that hold the counterweight.
i
Use a 3 mm allen wrench.
•
Remove the counterweight.
•
Measure the length of the cable from the flange facing.
i
Add the length of the counterweight to get the total probe length. Subtract the length of the
cable engaged in the counterweight. Refer to the diagram after this procedure.
•
Cut the cable to the correct length.
•
Attach the cable to the counterweight. Tighten the socket set screws.
i
Use a 3 mm allen wrench.
INFORMATION!
This information is for :
•
Ø4mm/0.15" double cable,
•
single rod,
•
Ø2 mm/0.08" single cable and
•
Ø4 mm/0.15" single cable probes only
WARNING!
Do not change the length of coaxial, Ø8 mm/0.3" single cable and double rod probes. This will
damage the probe.
INFORMATION!
If you cannot measure the length of the probe, you can use Quick Setup > Setup Mode > Auto
Quick Setup > Setup Mode > Auto
Quick Setup > Setup Mode > Auto
Quick Setup > Setup Mode > Auto
Probe Length
Probe Length
Probe Length
Probe Length as an alternative. But you must do this procedure when the tank is empty.
HB_OPTIFLEX1300_EN_D4_080428.book Page 100 Tuesday, April 29, 2008 2:47 PM