INSTALLATION
26
OPTIFLEX 1300 C
www.krohne.com
01/2008 • 4000172301 - HB OPTIFLEX 1300 R02 en
CAUTION!
Do not put the process connection near to the product inlet. If the product that enters the tank
touches the probe, the instrument will measure incorrectly.
Figure 3-15:
Do not put the instrument near to a product inlet
1
The instrument is in the correct position.
2
The instrument is too near to the product inlet.
3
If it is not possible to put the instrument in the recommended position, install a deflector pipe.
Figure 3-16:
How to prevent build up of product around the process connection
1
If product particles are likely to collect in holes, a nozzle is not recommended.
2
Attach the flange directly to the tank.
3
Use a thread connection to attach the instrument to the tank.