9
TECHNICAL DATA
140
OPTIFLEX 1300 C
www.krohne.com
01/2008 • 4000172301 - HB OPTIFLEX 1300 R02 en
Options and Accessories
Options
Integrated LCD display with sun cover (-20
…
+60
°
C
/ -4
…
+140
°
F);
8
2nd current output;
ESD protection (max. 30 kV);
Secondary METAGLAS seal for dangerous products
(ammonia, chlorine, ...);
Remote housing connected to the probe via a
flexible conduit
Standard lengths: 2 m / 6.6 ft, 4.5 m / 14.8 ft,
9.5 m / 31.2 ft and 14.5 m / 47.6 ft
Accessories
Weather protection
1
optional
2
refer to the pressure/temperature table for probe selection. 315
°
C / 599
°
F pending for the high-temperature (HT) ver-
sion of the Ø2 mm / 0.15" single cable probe.
3
refer to the pressure/temperature table for probe selection
4
Hastelloy
®
C-22 (2.4602) on request for the Ø2 mm / 0.15" single cable probe
5
others on request
6
min./max. value for an output of 22 mA at the terminal
7
min/max. value for an output of 22 mA at the terminal (additional power supply needed - output only)
8
if the ambient temperature is not in these limits, the display switches off
HB_OPTIFLEX1300_EN_D4_080428.book Page 140 Tuesday, April 29, 2008 2:47 PM