OPERATION
6
101
OPTIFLEX 1300 C
www.krohne.com
01/2008 • 4000172301 - HB OPTIFLEX 1300 R02 en
•
Go to Supervisor > Advanced setup > Installation > Probe length
Supervisor > Advanced setup > Installation > Probe length
Supervisor > Advanced setup > Installation > Probe length
Supervisor > Advanced setup > Installation > Probe length.
•
Type in the new value. Press
^
.
•
Press > and (Esc) at the same time to exit to the "save settings" window.
•
Select Save
Save
Save
Save and press
^
.
Dimensions in mm
Dimensions in inches
INFORMATION!
If you cannot measure the length of the probe, you can use Quick Setup > Setup Mode > Auto
Quick Setup > Setup Mode > Auto
Quick Setup > Setup Mode > Auto
Quick Setup > Setup Mode > Auto
Probe Length
Probe Length
Probe Length
Probe Length as an alternative. But you must do this procedure when the tank is empty.
Figure 6-13:
Dimensions of the counterweights
1
Ø2 mm/0.08" single cable probe
2
Ø4 mm/0.15" single cable probe
3
Ø4 mm/0.15" double cable probe
Probe type
Dimensions [mm]
a
b
Øc
Single cable Ø2 mm
15
100
14
Single cable Ø4 mm
36
100
20
Double cable Ø4 mm
36
60
38
Probe type
Dimensions [inches]
a
b
Øc
Single cable Ø0.08"
0.6
3.9
0.5
Single cable Ø0.15"
1.4
3.9
0.8
Double cable Ø0.15"
1.4
2.4
1.5
a
b
c
a
b
c
a
b
c
1
2
3