Parameter
5
1
KEB COMBIVERT F5-G / C / B
10
Name: Basis
10.05.04
Chapter
Section
Page
Date
©
KEB Antriebstechnik, 2002
All Rights reserved
Parameter
Adr.
Control Properties min.
max.
Step default [?] see on Page
in 16 QS no.
0E10 B C g G M S A R - - - 0
65535
1
0
-
6.1.21
in 17 temp.- mode
0E11 - - - G M S A R - - - LTK
LTK
1
LTK
-
6.1.21
in 22 user parameter 1
0E16 B C g G M S A - - - - 0
65535
1
0
-
6.1.21
in 23 user parameter 2
0E17 B C g G M S A - - - - 0
65535
1
0
-
6.1.21
in 24 last error
0E18 B C g G M S A R - E - 0
255
-
0
-
6.1.21
in 25 error diagnosis
0E19 B C g G M S A R P - - 0
65535
1
0 hex
6.1.22
in 26 E.OC error counter
0E1A B C g G M S A R - - - 0
65535
1
0
-
6.1.22
in 27 E.OL error counter
0E1B B C g G M S A R - - - 0
65535
1
0
-
6.1.22
in 28 E.OP error counter
0E1C B C g G M S A R - - - 0
65535
1
0
-
6.1.22
in 29 E.OH error counter
0E1D B C g G M S A R - - - 0
65535
1
0
-
6.1.22
in 30 E.OHI error counter
0E1E B C g G M S A R - - - 0
65535
1
0
-
6.1.22
le 0 comparison level 0
0D00 B C g G - - - - P - - -30000,00
30000,00
0,01
0,00
-
6.3.15, 6.9.13
le 1 comparison level 1
0D01 B C g G - - - - P - - -30000,00
30000,00
0,01
0,00
-
6.3.15, 6.9.13
le 2 comparison level 2
0D02 B C g G - - - - P - - -30000,00
30000,00
0,01
100,00
-
6.3.15, 6.9.13
le 3 comparison level 3
0D03 B C g G - - - - P - - -30000,00
30000,00
0,01
4,00
-
6.3.15, 6.9.13
le 4 comparison level 4
0D04 B C g G - - - - P - - -30000,00
30000,00
0,01
0,00
-
6.3.15, 6.9.13
le 5 comparison level 5
0D05 B C g G - - - - P - - -30000,00
30000,00
0,01
0,00
-
6.3.15, 6.9.13
le 6 comparison level 6
0D06 B C g G - - - - P - - -30000,00
30000,00
0,01
0,00
-
6.3.15, 6.9.13
le 7 comparison level 7
0D07 B C g G - - - - P - - -30000,00
30000,00
0,01
0,00
-
6.3.15, 6.9.13
le 8 hysteresis 0
0D08 B C g G M S A - P - - 0,00
300,00
0,01
0,00
-
6.3.15
le 9 hysteresis 1
0D09 B C g G M S A - P - - 0,00
300,00
0,01
0,00
-
6.3.15
le 10 hysteresis 2
0D0A B C g G M S A - P - - 0,00
300,00
0,01
5,00
-
6.3.15
le 11 hysteresis 3
0D0B B C g G M S A - P - - 0,00
300,00
0,01
0,50
-
6.3.15
le 12 hysteresis 4
0D0C B C g G M S A - P - - 0,00
300,00
0,01
0,00
-
6.3.15
le 13 hysteresis 5
0D0D B C g G M S A - P - - 0,00
300,00
0,01
0,00
-
6.3.15
le 14 hysteresis 6
0D0E B C g G M S A - P - - 0,00
300,00
0,01
0,00
-
6.3.15
le 15 hysteresis 7
0D0F B C g G M S A - P - - 0,00
300,00
0,01
0,00
-
6.3.15
le 16 freq/speed hysteresis
0D10 B C g G - - - - - - V 0
20
0,0125
0,8
Hz
6.3.15
le 17 timer 1 start inp. sel.
0D11 B C g G M S A - - E - 0
4095
1
0
-
6.3.8, 6.9.12
le 18 timer 1 start condition
0D12 B C g G M S A - - E - 0
7
1
0
-
6.3.8, 6.9.12
le 19 timer 1 reset inp. sel.
0D13 B C g G M S A - - E - 0
4095
1
0
-
6.3.8, 6.9.12
le 20 timer 1 reset condition
0D14 B C g G M S A - - E - 0
31
1
16
-
6.9.13
le 21 timer 1 mode
0D15 B C g G M S A - - - - 0
31
1
0
-
6.9.11
le 22 timer 2 start inp. sel.
0D16 B C g G M S A - - E - 0
4095
1
0
-
6.3.8, 6.9.12
le 23 timer 2 start condition
0D17 B C g G M S A - - E - 0
7
1
0
-
6.3.8, 6.9.12
le 24 timer 2 reset inp. sel.
0D18 B C g G M S A - - E - 0
4095
1
0
-
6.3.8, 6.9.12
le 25 timer 2 reset condition
0D19 B C g G M S A - - E - 0
31
1
16
-
6.9.13
le 26 timer 2 mode
0D1A B C g G M S A - - - - 0
31
1
0
-
6.9.11
op 0 reference source
03 00 B C g - - - - - P E - 0
6
1
0
-
6.4.4, 6.9.9
op 0 reference source
03 00 - - - G M S A - P E - 0
9
1
0
-
6.4.4, 6.9.9
op 1 rotation source
03 01 B C g G - - - - P E - 0
9
1
2
-
6.4.6, 6.9.9
op 2 rotation setting
03 02 B C g G M S A - P E - 0
2
1
0
-
6.4.6
op 3 reference setting
03 03 B C g G - - - - P - V -400
400
0,0125
0
Hz
6.4.4
op 5 reference setting %
03 05 B C g G M S A - P - - -100,0
100,0
0,1
0,0
%
6.4.4
op 6 min. reference forward
03 06 B C g G - - - - P - V 0
400
0,0125
0
Hz
6.4.11
op 7 min. reference reverse
03 07 B C g G - - - - P - V -0,0125
400
0,0125
-0,0125
Hz
6.4.11
op10 max. reference forward
03 0A B C g G - - - - P - V 0
400
0,0125
0
Hz
6.4.11
op11 max. reference reverse
03 0B B C g G - - - - P - V -0,0125
400
0,0125
-0,0125
Hz
6.4.11
op14 abs. max. reference for
03 0E B C g G - - - - P - V 0
400
0,0125
400
Hz
6.4.11
op15 abs. max. reference rev
03 0F B C g G - - - - P - V -0,0125
400
0,0125
-0,0125
Hz
6.4.11
op18 step value rot. source
03 12 B C g G - - - - P E - 0
9
1
2
-
6.4.9
op19 step value input sel. 1
03 13 B C g G M S A - - E - 0
4095
1
16
-
6.4.9, 6.3.8
op20 step value input sel. 2
03 14 B C g G M S A - - E - 0
4095
1
32
-
6.4.9, 6.3.8
op21 step value 1
03 15 B C g G - - - - P - V -400
400
0,0125
5
Hz
6.4.9
op22 step value 2
03 16 B C g G - - - - P - V -400
400
0,0125
50
Hz
6.4.9
op23 step value 3
03 17 B C g G - - - - P - V -400
400
0,0125
70
Hz
6.4.9
op27 acc dec mode
03 1B B C g G M S A - P E - 0
255
1
0
-
6.4.16
op28 acc. time forward
03 1C B C g G M S A - P - - 0,00
300,00
0,01
5,00
s
6.4.13
op29 acc. time reverse
03 1D B C g G M S A - P - - -0,01
300,00
0,01
-0,01
s
6.4.13
op30 dec. time forward
03 1E B C g G M S A - P - - -0,01
300,00
0,01
5,00
s
6.4.13
op31 dec. time reverse
03 1F B C g G M S A - P - - -0,01
300,00
0,01
-0,01
s
6.4.13
op32 s-curve time acc. for.
03 20 B C g G M S A - P - - 0,00
5,00
0,01
0,00
s
6.4.14
op33 s-curve time acc. rev.
03 21 B C g G M S A - P - - -0,01
5,00
0,01
-0,01
s
6.4.14
op34 s-curve time dec. for.
03 22 B C g G M S A - P - - -0,01
5,00
0,01
-0,01
s
6.4.14
op35 s-curve time dec. rev.
03 23 B C g G M S A - P - - -0,01
5,00
0,01
-0,01
s
6.4.14
op36 min. output freq. for
03 24 B C g G - - A - P - V 0
400
0,0125
0
Hz
op37 min. output freq. rev
03 25 B C g G - - A - P - V -0,0125
400
0,0125
-0,0125
Hz
op40 max. output val. for.
03 28 B C g G - - - - P - V 0
400
0,0125
400
Hz
6.4.15, 6.7.5
op41 max. output val. rev.
03 29 B C g G - - - - P - V -0,0125
400
0,0125
-0,0125
Hz
6.4.15, 6.7.5
op44 ext. funct. mode/src
03 2C - C - G M S A - P E - 0
63
1
0
-
6.9.27, 6.9.29
op45 ext. funct. dig. source
03 2D - C - G M S A - P - - 0,00
100,00
0,01
0,00
%
6.9.27, 6.9.29
op46 ext. funct. acc/dec time
03 2E - C - G M S A - P - - 0,00
20,00
0,01
10,00
s
6.9.27, 6.9.30
op47 sweep-gen. acc. time
03 2F - C - G M S A - P - - 0,00
20,00
0,01
10,00
s
6.9.27
op48 sweep-gen. dec. time
03 30 - C - G M S A - P - - 0,00
20,00
0,01
10,00
s
6.9.27
op49 diam. corr. dmin/dmax
03 31 - C - G M S A - P - - 0,010
0,990
0,001
0,500
-
6.9.30
op50 motorpoti function
03 32 B C g G M S A - - E - 0
3
1
0
-
6.9.8
op52 motorpoti value
03 34 B C g G M S A - P - - -100,00
100,00
0,01
0,00
%
6.9.9