6
6
11
15
KEB COMBIVERT F5-M / S
Name: Basis
06.05.04
Section
Page
Date
©
KEB Antriebstechnik, 2002
All Rights reserved
Chapter
Functional Desription
Positioning and Synchronous Control
The position of S! and S2 in the graphic below, is dependent on the parameters
cS.1, PS.1, PS.0, ec.39.
Basically applies:
-speed-controlled open, but feedback always with gear factor = 1
-Posi S1,S2 open
-Posi over output S2 closed, gear factor for the speed precontrol
-Synchronous Mode S2 closed
-ec.39 =1 , S1 closed, gear factor enters into the speed detection
The summing-up of the basic
setting
ec.4
ec.5
-
S1
ec.33
ec.31
ec.29
ec.14
ec.15
-
S2
ec.34
ec.32
ec.30
ru.54
Position detection
Evaluation
Gear factor
Gear factor
Bit -No. Decimal value Input
Terminal
0
1
ST (prog. input Ñcontrol release / resetì)
X2A.16
1
2
RST (prog. input Ñresetì)
X2A.17
2
4
F (prog. input Ñforwardì)
X2A.14
3
8
R (prog. input Ñreverseì)
X2A.15
4
16
I1 (prog. input 1)
X2A.10
5
32
I2 (prog. input 2)
X2A.11
6
64
I3 (prog. input 3)
X2A.12
7
128
I4 (prog. input 4)
X2A.13
8
256
IA (internal input A)
none
9
512
IB (internal input B)
none
10
1024
IC (internal input C)
none
11
2048
ID (internal input D)
none
Posi/Synch input select (PS.2)
If the Posi Mode is selected with PS.0, the posi-module can be activated by setting
the input defined with PS.2.