KEB COMBIVERT F5
Name: Basis
04.05.04
6
Section
Page
Date
©
KEB Antriebstechnik, 2002
All rights reserved
Chapter
Functional Description
CP-Parameter Definition
Table 1 Unit
Value Unit
Value Unit
Value Unit
Value Unit
0 none
16 km/h
32 K
48 lbin
1 mm
17 1/min
33 m
Ω
49 in/s
2 cm
18 Hz
34
Ω
50 ft/s
3 m
19 kHz
35 k
Ω
51 ft/min
4 km
20 mV
36 INC
52 ft/s²
5 g
21 V
37 %
53 ft/s³
6 kg
22 kV
38 KWh
54 MPH
7 us
23 mW
39 mH
55 kp
8 ms
24 W
40 -
56 psi
9 s
25 kW
41 -
57 °F
10 h
26 VA
42 in
58 -
11 Nm
27 kVA
43 ft
59 -
12 kNm
28 mA
44 yd
60 -
13 m/s
29 A
45 oz
61 -
14 m/s
2
30 kA
46 lb
62 -
15 m/s
3
31 °C
47 lbft
63 -
Table 2
Calculation mode
(selected par ud.20) x
ud.19
= CP.xx
ud.18
ud.19
= CP.xx
(selected par ud.20) x ud.18
Value
0
64
-
-
free
free
Function
Value Representation
0
0 decimal places
256
1 demical place
512
2 decimal places
768
3 decimal places
1024
4 decimal places
1280
variable decimal places
1536
Hexadecimal
-
free
Table 3
Representation
Example
The actual frequency shall be displayed in CP.1 in rpm. Display standardization from
set 4.
ud.15 = 1
; CP.1
ud.16 = 0203h
; Actual frequency ru.3
ud.17 = 4352
; Display in current set, display standardization from set 4
Satz 4 ud.18 = 80
; Conversion from 1/80 Hz into rpm without pole pair number
Satz 4 ud.19 = 60
Satz 4 ud.20 = 0
; no Offset
Satz 4 ud.21 = 17
; Unit rpm; direct calculation mode; no decimal places
The
unstandardized
value is always
used for the
„selected
parameter“ !