Parameter
5
1
9
KEB COMBIVERT F5-G / C / B
Name: Basis
10.05.04
Section
Page
Date
©
KEB Antriebstechnik, 2002
All Rights reserved
Chapter
Parameter
Adr.
Control Properties min.
max.
Step default [?] see on Page
5
do29 inv. flags for OA
0C1D B C g G M S A - P E - 0
255
1
0
-
6.3.17
do30 inv. flags for OB
0C1E B C g G M S A - P E - 0
255
1
0
-
6.3.17
do31 inv. flags for OC
0C1F B C g G M S A - P E - 0
255
1
0
-
6.3.17
do32 inv. flags for OD
0C20 B C g G M S A - P E - 0
255
1
0
-
6.3.17
do33 flag select. for O1
0C21 - C g G M S A - P E - 0
255
1
1
-
6.3.17
do34 flag select. for O2
0C22 - C g G M S A - P E - 0
255
1
2
-
6.3.17
do35 flag select. for R1
0C23 B C g G M S A - P E - 0
255
1
4
-
6.3.17
do36 flag select. for R2
0C24 B C g G M S - - P E - 0
255
1
8
-
6.3.17
do37 flag select. for OA
0C25 B C g G M S A - P E - 0
255
1
16
-
6.3.17
do38 flag select. for OB
0C26 B C g G M S A - P E - 0
255
1
32
-
6.3.17
do39 flag select. for OC
0C27 B C g G M S A - P E - 0
255
1
64
-
6.3.17
do40 flag select. for OD
0C28 B C g G M S A - P E - 0
255
1
128
-
6.3.17
do41 AND conn. for outputs
0C29 B C g G M S A - P E - 0
255
1
0
-
6.3.17
do42 inverted outputs
0C2A B C g G M S A - P E - 0
255
1
0
-
6.3.18
do43 cond. 0 filter time
0C2B - C - G M S A - P - - 0
1000
1
0
ms
6.3.12
do44 cond. 1 filter time
0C2C - C - G M S A - P - - 0
1000
1
0
ms
6.3.12
do51 hardw. outp. allocation
0C33 - C - G M S A - P - - 0
255
1
228
-
dr 0 DASM rated current
06 00 B C g G M - A - P - - 0,0
710
0,1
LTK
A
6.6.3
dr 1 DASM rated speed
06 01 B C g G M - A - P - - 0
64000
1
LTK
rpm
6.6.3
dr 2 DASM rated voltage
06 02 B - g G M - A - P - - 120
500
1
LTK
V
6.6.3
dr 3 DASM rated power
06 03 - C - G M - A - P - - 0,35
400,00
0,01
LTK
kW
6.6.3
dr 4 DASM rated cos(phi)
06 04 B C g G M - A - P - - 0,50
1,00
0,01
LTK
-
6.6.3
dr 5 DASM rated frequency
06 05 B C g G M - A - P - - 0,0
1600,0
0,1
LTK
Hz
6.6.3
dr 6 DASM stator resistance
06 06 B C g G M - A - P - - 0,000
50,000
0,001
LTK Ohm 6.6.4
dr 9 breakdown factor
06 09 B C g G - - A - P - - 0,5
4,0
0,1
2,5
-
dr 11 motorprotection mode
06 0B B C g G M - A - P - - 0
1
1
1
-
6.7.16
dr 12 motorprot. rated current
06 0C B C g G M - A - P - - 0,0
710,0
0,1
LTK
A
6.7.16
ec 0 encoder 1 interface
10 00 - - - G M S A - - X - -127
127
1
GBK
-
6.10.10
ec 1 encoder 1 (inc/r)
10 01 - - - G M S A - - - - GBK
GBK
1
GBK
inc
6.10.10
ec 3 time 1 for speed calc.
10 03 - - - G M S A - - - - 0
9
1
3
-
6.10.10
ec 4 gear 1 numerator
10 04 - - - G M S A - - - - -10000
10000
1
1000
-
6.10.11
ec 5 gear 1 determinator
10 05 - - - G M S A - - - - 1
10000
1
1000
-
6.10.11
ec 6 enc.1 rotation
10 06 - - - G M S A - - - - 0
19
1
0
-
6.10.11
ec 7 enc.1 trigger
10 07 - - - G M S - - - - - GBK
GBK
1
GBK
-
6.10.11
ec10 encoder 2 interface
10 0A - - - G M S A - - X - -127
127
1
GBK
-
6.10.6, 6.10.10
ec11 encoder 2 (inc/r)
10 0B - - - G M S A - - - - GBK
GBK
1
GBK
inc
6.10.10
ec13 time 2 for speed calc.
10 0D - - - G M S A - - - - 0
9
1
3
-
6.10.10
ec14 gear 2 numerator
10 0E - - - G M S A - - - - -10000
10000
1
1000
-
6.10.11
ec15 gear 2 determinator
10 0F - - - G M S A - - - - 1
10000
1
1000
-
6.10.11
ec16 enc.2 rotation
10 10 - - - G M S A - - - - 0
19
1
0
-
6.10.11
ec17 enc.2 trigger
10 11 - - - G M S - - - - - GBK
GBK
1
GBK
-
6.10.11
ec20 enc.2 operating mode
10 14 - - - G M S A - - - - 0
1
1
0
-
6.10.7
ec21 SSI multiturn res.
10 15 - - - G M S - - - - - 0
13
1
12
-
6.10.13
ec22 SSI clock frq. sel.
10 16 - - - G M S - - - - - 0
1
1
0
-
6.10.13
ec23 SSI data code
10 17 - - - G M S - - - - - 0
1
1
1
-
6.10.13
ec25 nominal tacho speed
10 19 - - - G M S - - - - - 1
16000
1
1500
rpm
6.10.13
ec27 operation mode output
10 1A - - - G M S - - - E - 0
47
1
0
-
6.10.12
ec31 abs. position ch1
10 1F - - - G M S A - - - - -2^31
2^31-1
1
0
inc
6.10.13
ec32 abs. position ch2
10 20 - - - G M S - - - - - -2^31
2^31-1
1
0
inc
6.10.13
ec36 enc.1 encoder type
10 24 - - - G M S - - - - - 0
255
1
0
-
6.10.13
ec37 enc.1 encoder status
10 25 - - - G M S - - - - - 0
255
1
0
-
6.10.13
ec38 enc.1 encoder r/w
10 26 - - - G M S - - - E - 0
2
1
0
-
6.10.13
fr 1 copy parameter set
09 01 B C g G M S A - P E - -4
7
1
0
-
6.8.4
fr 2 parameter set source
09 02 B C g G M S A - - E - 0
5
1
0
-
6.8.5
fr 3 parameter set lock
09 03 B C g G M S A - - E - 0
255
1
0
-
6.8.8
fr 4 parameter set setting
09 04 B C g G M S A - - E - 0
7
1
0
-
6.8.5
fr 5 set activation delay
09 05 B C g G M S A - P - - 0,00
2,55
0,01
0,00
s
6.8.8, 6.9.31
fr 6 set deactivation delay
09 06 B C g G M S A - P - - 0,00
2,55
0,01
0,00
s
6.8.8, 6.9.31
fr 7 paraset input sel.
09 07 B C g G M S A - - E - 0
4095
1
0
-
6.8.6, 6.3.8
fr 8 motor set classification
09 08 B C g G M - A - P - - 0
7
1
0
-
6.7.14
fr 9 bus parameter set
09 09 B C g G M S A - - - - -1
7
1
0
-
6.8.4
fr 10 load mot.dependent para.
09 0A - C - G - - - - P E - 3
3
1
3
-
6.6.6
fr 11 reset set input sel.
09 0B B C g G M S A - - E - 0
4095
1
0
-
6.8.7, 6.3.8
in 0 inverter type
0E00 B C g G M S A R - - - LTK
LTK
1
LTK
hex
6.1.19
in 1 rated inverter current
0E01 B C g G M S A R - - - LTK
LTK
0,1
LTK
A
6.1.19
in 3 max. carrier frequency
0E03 B C g G M S A R - - - LTK
LTK
1
LTK
-
6.1.20
in 4 rated carrier frequency
0E04 B C g G M S A R - - - LTK
LTK
1
LTK
-
6.1.20
in 6 software version
0E06 B C g G M S A R - - - SW
SW
0,01
SW
-
6.1.20
in 7 software date
0E07 B C g G M S A R - - - SW
SW
0,1
SW
-
6.1.20
in 8 software version p. unit
0E08 - - g - - - - R - - - LTK
LTK
1
LTK
-
in 9 software date p. unit
0E09 - - g - - - - R - - - LTK
LTK
1
LTK
-
in 10 serial no. (date)
0E0A B C g G M S A R - - - 0
65535
1
0
-
6.1.21
in 11 serial no. (count)
0E0B B C g G M S A R - - - 0
65535
1
0
-
6.1.21
in 12 serial no. (AB-no. high)
0E0C B C g G M S A R - - - 0
65535
1
0
-
6.1.21
in 13 serial no. (AB-no. low)
0E0D B C g G M S A R - - - 0
65535
1
0
-
6.1.21
in 14 customer no. high
0E0E B C g G M S A R - - - 0
65535
1
0
-
6.1.21
in.15 customer no. low
0E0F B C g G M S A R - - - 0
65535
1
0
-
6.1.21