At using the brake control the direction of rotation (oP.1) may not be set to „7“, because
then no Low-Speed-Signal (LS) is output.
Used Parameters
Pn.34
0422h
-
✔
✔
0
4
1
0
-
Pn.35
0423h
-
✔
-
0,00 s
100,00 s
0,01 s
0,25 s
-
Pn.36
0424h
-
✔
-
0,00 s
100,00 s
0,01 s
0,25 s
-
Pn.37
0425h
-
✔
-
-20 Hz
20 Hz
0,0125 Hz
0 Hz
F5-G/B depending on ud.2
0425h
-
✔
-
-600 rpm
600 rpm
0,125 rpm
0 Hz
F5-M/S depending on ud.2
Pn.39
0427h
-
✔
-
0,00 s
100,00 s
0,01 s
0,25 s
-
Pn.40
0428h
-
✔
-
0,00 s
100,00 s
0,01 s
0,25 s
-
Pn.41
0429h
-
✔
-
-20 Hz
20 Hz
0,0125 Hz
0 Hz
F5-G/B depending on ud.2
0429h
-
✔
-
-600 rpm
600 rpm
0,125 rpm
0 Hz
F5-M/S depending on ud.2
Pn.43
042Bh
-
✔
-
0
100 %
1 %
0 %
-
Start value (Pn.37)
Stop value (Pn.41)
The adjustable start/stop value stands in direct connection with the necessary holding
torque. The preadjustment, according to following formula, is valid for rated motor
torques:
(no-load motor speed - rated motor speed) x rated motor frequency
Start-/Stop value=
no-load motor speed
(1500rpm
- 1420rpm
) x 50Hz
Example:
= 2,67 Hz
1500rpm
The direction into which the holding torque shall take effect is determined by the sign.
The parameters are set-programmable.