ADM 6725 E10
KA
T
5 - 13
Program Branch MEASURING
5.0 cm/s
+Cut-off Flow
Enter here the cut-off flow limit for positive
measuring values. Should the measured value
fall below this threshold, a flow velocity of 0
cm/s will be used for further calculation.
-5.0 cm/s
-Cut-off Flow
Enter here the cut-off flow limit for negative
measuring values. Should the measured value
rise above this threshold, a flow velocity of 0
cm/s will be used for further calculation.
In mode Cut-off flow/>ABSOLUTE<, only one limit value has to be entered for the cut-off
flow function:
5.0 cm/s
Cut-off Flow
The limit comparison will be performed using
the absolute numerical value of the measured
flow velocity.
Note:
For the user definition of the cut-off flow limit, the conventions applicable for the
SUPER USER MODE (see introduction in chapter 9) are valid.
5.3.4 Flow Totalisers
FLUXUS has the facility to work as a flow totaliser. There are two flow totalisers in-built.
One counts the total quantity throughput in positive flow direction, the other counts in
negative flow direction.
Flow totalising for each independent measuring channel means:
•
FLUXUS measures the liquid volume throughput which has passed the respective
measuring point
within a given time.
•
The corresponding unit of measurement, which was defined in program branch
OUTPUT OPTIONS, will be used for totalisation.
54.5 m3/h
A: Volume Flow
M8
The two in-built flow totalisers can be
activated at the same time from display
'Volume Flow':
Press
O N
O
to activate the flow totalisers.
Attention!
•
Activate the flow totalisers only
after
the first measuring value has been
displayed. Otherwise, there will be no counting up.
•
To activate the flow totalisers for a
certain measuring channel
, this channel
must be shown on the display.
54.5 m3/h
A: 32.5 m3
M9
Here you can see on the display the totalised
flow volume which has passed the measuring
point in one flow direction since the activation
of the totalisers.
FLUXUS can also show the respective flow volume with alternating flow directions:
Содержание FLUXUS ADM 6725
Страница 1: ...Operating Instructions RESET INIT 3x OFF ON PORTABLE ULTRASONIC FLOWMETER FLUXUS ADM 6725...
Страница 4: ...ADM 6725 E10 KAT...
Страница 14: ...1 4 ADM 6725 E10 KAT Functional Description This page has been left empty intentionally...
Страница 28: ...2 14 FLUXUS ADM 6725 E10 KAT Description of Flowmeter This page has been left empty intentionally...
Страница 69: ...ADM 6725 E10 KAT 6 9 Program Branch OUTPUT OPTIONS 2700 s Storage Rate O11 6a Next display e g current loop...
Страница 70: ...6 10 ADM 6725 E10 KAT Program Branch OUTPUT OPTIONS This page has been left empty intentionally...
Страница 104: ...10 6 ADM 6725 E10 KAT Virtual Calculation Channels This page has been left blank intentionally...
Страница 112: ...11 8 ADM 6725 E10 KAT Heat Quantity Measurement This page has been left empty intentionally...
Страница 122: ...12 10 ADM 6725 E10 KAT Wall Thickness Measurement This page has been left blank intentionally...
Страница 132: ...Process Interfaces 13 10 ADM 6725 E10 KAT This page has been left blank intentionally...
Страница 138: ...14 6 ADM 6725 E10 KAT Errors This page has been left blank intentionally...