Virtual Calculation Channels
The tables below are a summary of the different abbreviations used in the
PARAMETER menu of the virtual channels and the different inputs from channels A
and B required to obtain various readings.
Quantity of
Measurement:
Abbreviation:
Flow Velocity
VELOC
Volume Flow
VOLUM
Mass Flow
MASS
Heat Flow
HEAT
Type of
measurement taken
through virtual
channels
Required input values
through Channel A
(CH1)
Required input values
through Channel B
(CH2)
VELOC VOLUM MASS HEAT VELOC VOLUM MASS HEAT
Flow Velocity
X
X
X
X
X
X
X
X
Volume Flow
X
X
X
X
X
X
Mass Flow
X
X
X
X
X
X
Heat Flow
X
X
Example 1:
The difference of the volume flows (respectively the difference volume) of the channels A and B
shall be determined. The quantity of measurement of channel A can be: volume flow, or mass flow,
or heat flow. The quantity of measurement of channel B can also be the volume flow, or the mass
flow, or the heat flow. The two quantities of measurement might be different (channel A = heat flow;
channel B = volume flow).
Example 2:
For determining the heat flow difference, the quantity of measurement must be the heat flow for both
input channels A and B.
+Cut-off Flow
1.00 m3/h
-Cut-off Flow
-2.50 m3/h
Two cut-off flows can be defined for each calculation channel:
+Cut-off Flow:
In this example all
positive
calculation
values, falling below this threshold, will
be set to 0.00.
−
Cut-off Flow:
In this example all
negative
calculation
values, rising above this threshold, will
be set to 0.00.
That means for this example: All calculation values ranging
between –2.5 ... 1.0 m³/h will be negated.
Store Meas.Data
>NO< yes
...
The options for the storage or the output of measured values
can be set in the same way as for the physical channels.
As previously explained, the calculation channels are not filtered, therefore the
dialogue box for the setting of the damping has been removed from the menu.
Содержание FLUXUS ADM 6725
Страница 1: ...Operating Instructions RESET INIT 3x OFF ON PORTABLE ULTRASONIC FLOWMETER FLUXUS ADM 6725...
Страница 4: ...ADM 6725 E10 KAT...
Страница 14: ...1 4 ADM 6725 E10 KAT Functional Description This page has been left empty intentionally...
Страница 28: ...2 14 FLUXUS ADM 6725 E10 KAT Description of Flowmeter This page has been left empty intentionally...
Страница 69: ...ADM 6725 E10 KAT 6 9 Program Branch OUTPUT OPTIONS 2700 s Storage Rate O11 6a Next display e g current loop...
Страница 70: ...6 10 ADM 6725 E10 KAT Program Branch OUTPUT OPTIONS This page has been left empty intentionally...
Страница 104: ...10 6 ADM 6725 E10 KAT Virtual Calculation Channels This page has been left blank intentionally...
Страница 112: ...11 8 ADM 6725 E10 KAT Heat Quantity Measurement This page has been left empty intentionally...
Страница 122: ...12 10 ADM 6725 E10 KAT Wall Thickness Measurement This page has been left blank intentionally...
Страница 132: ...Process Interfaces 13 10 ADM 6725 E10 KAT This page has been left blank intentionally...
Страница 138: ...14 6 ADM 6725 E10 KAT Errors This page has been left blank intentionally...