ADM 6725 E10
KA
T
5 - 9
Program Branch MEASURING
With a sensor
positioning
rail
Use the sensor positioning rail to mount the transducers on the pipe if
•
the reflection mode has been selected,
•
the outside pipe diameter ranges up to 450 mm.
1st step
The mounting fixture on the chain snaps into the groove at the ends of the sensor
positioning rail. The chain and the spring on the mounting fixture will enable the
application of the necessary mounting pressure between rail and pipe.
Mounting fixture
Mounting
fixture
Sensor
positioning
rail
Sensor
positioning rail
2nd Step
Slide track
device
Transducer
Slide track
device with
transducer
The separate slide track device which
carries the transducer in the sensor
positioning rail snaps into the groove of the
transducer.
Attention!
Do not bend the transducer cable. With larger transducer distances, guide
transducer cable through side fronts of sensor positioning rail before the positioning
rail is being fastened.
3rd Step
•
Fit the transducers through the opening of
the positioning rail as shown with the slide
track devices snapped in place.
•
Press the large knob screw of the slide
track device against the pipe.
•
Turn the knob screw by 90 degrees until it
snaps into the rail.
%
Ball chain or Tension strap
&
Knob screw
Содержание FLUXUS ADM 6725
Страница 1: ...Operating Instructions RESET INIT 3x OFF ON PORTABLE ULTRASONIC FLOWMETER FLUXUS ADM 6725...
Страница 4: ...ADM 6725 E10 KAT...
Страница 14: ...1 4 ADM 6725 E10 KAT Functional Description This page has been left empty intentionally...
Страница 28: ...2 14 FLUXUS ADM 6725 E10 KAT Description of Flowmeter This page has been left empty intentionally...
Страница 69: ...ADM 6725 E10 KAT 6 9 Program Branch OUTPUT OPTIONS 2700 s Storage Rate O11 6a Next display e g current loop...
Страница 70: ...6 10 ADM 6725 E10 KAT Program Branch OUTPUT OPTIONS This page has been left empty intentionally...
Страница 104: ...10 6 ADM 6725 E10 KAT Virtual Calculation Channels This page has been left blank intentionally...
Страница 112: ...11 8 ADM 6725 E10 KAT Heat Quantity Measurement This page has been left empty intentionally...
Страница 122: ...12 10 ADM 6725 E10 KAT Wall Thickness Measurement This page has been left blank intentionally...
Страница 132: ...Process Interfaces 13 10 ADM 6725 E10 KAT This page has been left blank intentionally...
Страница 138: ...14 6 ADM 6725 E10 KAT Errors This page has been left blank intentionally...