Tables
ADM 6725 E10
KA
T
17 - 1
Tables
The content of the tables has been compiled to help the user. The accuracy of the given data depends on the composition,
the temperature and the manufacturing process of the respective material. We do not accept liability for possible
inaccuracies.
Table 1 -
Pipe parameters stored
in FLUXUS
The following table shows the most important
parameters for pipe materials and/or linings, which are
already pre-programmed in the instrument. On request,
we can optimise the material list or extend it with new
materials, should this be required.
Material
c
trans
[m/s]
c
long
[m/s]
Aluminium
3100
Asbestos
cement
2200
Bitumen
2500
Lead
700
Ductile cast iron
2650
Glass
3400
Grey iron
2650
Rubber
1900
Plastic
1120
Copper
2260
Brass
2100
PE
2340
Perspex
2730
PP
2600
PVC
2395
Stainless steel
3230
Carbon steel
3230
PEEK
2550
Table 2 -
Pipe parameters not
stored in FLUXUS
Material
c
trans
[m/s] c
long
[m/s]
Platinum 1670
Polyethylene
925
Polystyrene 1150
PVC hard
1060
Quartz glass
3515
Silver 1590
Titanium 3180
Table 3 - Typical roughness coefficients for pipes
For your convenience, we have already pre-programmed common roughness coefficients for pipe materials.
The data are based upon experience with measurements performed with these pipe materials:
Pipewall material
Absolute roughness [
µ
m]
Drawn pipes of non-ferrous metal, glass, plastics and light
metal
0
... 1.5
Drawn steel pipes
10
... 50
•
fine-planed, polished surface
up to
10
•
planed surface
10
... 40
•
rough-planed surface
50
... 00
Welded steel pipes, new
50
... 100
•
long usage, cleaned
150
... 200
•
lightly and evenly rusted
up to
400
•
heavily encrusted
up to
3,000
Cast iron pipes
•
bitumen
lining
120
•
new, without lining
250
... 1000
•
rusted
1000
...
1500
•
encrusted
1500
...
3000
Table 4 - Media parameters
The instrument is already pre-programmed with the most frequently used media
parameters. On request, we can optimise this list or extend it with new media.
Содержание FLUXUS ADM 6725
Страница 1: ...Operating Instructions RESET INIT 3x OFF ON PORTABLE ULTRASONIC FLOWMETER FLUXUS ADM 6725...
Страница 4: ...ADM 6725 E10 KAT...
Страница 14: ...1 4 ADM 6725 E10 KAT Functional Description This page has been left empty intentionally...
Страница 28: ...2 14 FLUXUS ADM 6725 E10 KAT Description of Flowmeter This page has been left empty intentionally...
Страница 69: ...ADM 6725 E10 KAT 6 9 Program Branch OUTPUT OPTIONS 2700 s Storage Rate O11 6a Next display e g current loop...
Страница 70: ...6 10 ADM 6725 E10 KAT Program Branch OUTPUT OPTIONS This page has been left empty intentionally...
Страница 104: ...10 6 ADM 6725 E10 KAT Virtual Calculation Channels This page has been left blank intentionally...
Страница 112: ...11 8 ADM 6725 E10 KAT Heat Quantity Measurement This page has been left empty intentionally...
Страница 122: ...12 10 ADM 6725 E10 KAT Wall Thickness Measurement This page has been left blank intentionally...
Страница 132: ...Process Interfaces 13 10 ADM 6725 E10 KAT This page has been left blank intentionally...
Страница 138: ...14 6 ADM 6725 E10 KAT Errors This page has been left blank intentionally...