3.1.4.1 Electrical connection specifications IOM
Power is provided by the machine's power supply unit.
Characteristic
Value
Rated voltage (stabilised) [V DC]
24
Current consump‐
tion SIGMA CONTROL 2 with IOM 1 [A]
2.4
Current consumption IOM 2 [A]
2.5
Current consumption IOM 3 [A]
1.6
IOM ≙ Input/Output module
Tab. 19 Power supply specifications
3.1.4.2 Maximum cable lengths
Input/Output
Cable length [m]
Analogue input current (AII),
Analogue input resistor (AIR)
Analogue output current (AOI)
< 30
Digital input (DI),
Digital output relay (DOR)
< 100
Digital output transistor (DOT)
< 30
Tab. 20 Cable lengths
3.1.4.3 Input/output modules – degree of protection
Characteristic
Value
Degree of protection within the machine
IP 54
Degree of protection within the control cabinet
IP 20
Tab. 21 Degree of protection, IOM
3.1.4.4 Input/output modules – dimensions
Characteristic
Value
Width [mm]
125
Height [mm]
250
Depth [mm]
44
Tab. 22 IOM dimensions
3.1.5 Sensors
Pressure transducer
Characteristic
Value
Output signal [mA]
0/4–20
3
Technical Specifications
3.1
Controller SIGMA CONTROL 2
No.: 9_9450 12 E
User Manual Controller
SIGMA CONTROL 2 SCREW FLUID ≥5.0.X
15