Message
Possible cause
Remedy
1257 W
AIR%d.0%d - short-
circuit
Short circuit in line for indicated analogue
input.
Check line paths and sensor
connection.
1258 W
AIR%d.0%d - open
circuit
Wire break in line for indicated analogue
input.
Check line paths and sensor
connection.
1259 W
AIR%d.0%d - sensor
fault
Sensor fault at indicated analogue input. Check line paths and sensor
connection.
1260 W
AIR%d.0%d - open
circuit
Wire break in line for indicated analogue
input.
Check line paths and sensor
connection.
1262 W
AIR%d.0%d - accidental
ground
Ground fault in line for ext. sensor at ana‐
logue input.
Check line paths and sensor
connection.
1263 W
AIR%d.0%d - short-
circuit
Short circuit in line for indicated analogue
input.
Check line paths and sensor
connection.
1264 W
AIR%d.0%d - open
circuit
Wire break in line for indicated analogue
input.
Check line paths and sensor
connection.
1265 W
AIR%d.0%d - sensor
fault
Sensor fault at indicated analogue input. Check line paths and sensor
connection.
1266 W
AIR%d.0%d - open
circuit
Wire break in line for indicated analogue
input.
Check line paths and sensor
connection.
1268 W
AIR%d.0%d - accidental
ground
Ground fault in line for ext. sensor at ana‐
logue input.
Check line paths and sensor
connection.
1269 W
AIR%d.0%d - short-
circuit
Short circuit in line for indicated analogue
input.
Check line paths and sensor
connection.
1270 W
AIR%d.0%d - open
circuit
Wire break in line for indicated analogue
input.
Check line paths and sensor
connection.
1271 W
AIR%d.0%d - sensor
fault
Sensor fault at indicated analogue input. Check line paths and sensor
connection.
1272 W
AIR%d.0%d - open
circuit
Wire break in line for indicated analogue
input.
Check line paths and sensor
connection.
1274 W
AIR%d.0%d - accidental
ground
Ground fault in line for ext. sensor at ana‐
logue input.
Check line paths and sensor
connection.
10 Fault Recognition and Rectification
10.3 Interpreting warning messages
No.: 9_9450 12 E
User Manual Controller
SIGMA CONTROL 2 SCREW FLUID ≥5.0.X