Fig. 4 MCSIO interfaces
Marking
Interface
Connection
X1
Ethernet 10/100 Base T
RJ 45 socket
X3
RS485–FC (USS interface)
9-pole SUB-D socket
X5
SD card, SD card slot
SD/SDHC card
X6
FE
Functional earth (FE)
X7
24 VDC, DII
Power supply 24 VDC
Digital inputs DII1.00–DII1.05
X8
DII/DOT
Digital inputs DII1.06–DII1.07
Digital outputs DOT1.00–DOT1.01
X9
AII/AIR
Analogue input current 0–20 mA,
AII1.00–AII1.01
Analogue input resistor AIR1.00–
AIR1.01
X10
DOR
Digital output relay 250 VAC, 4 A
DOR1.00–DOR1.04
The positions of the interfaces X1–X10 are marked on the rear of the controller.
Tab. 12 MCSIO interfaces
Identification with RFID Equipment Card
Characteristic
Value
Hardware on the SIGMA CONTROL 2 controller
RFID write/read device
Hardware (external)
RFID Equipment Card
Recognition distance [m]
max. 0.05
3
Technical Specifications
3.1
Controller SIGMA CONTROL 2
12
User Manual Controller
SIGMA CONTROL 2 SCREW FLUID ≥5.0.X
No.: 9_9450 12 E