Setting the temperature display units
Set the temperature unit for display:
Format
Example
°C
46°C
K
319K
°F
114°F
Tab. 50 Possible settings for the temperature unit
Precondition Access level 2 is activated.
1. Open the 5.1
<Configuration – General> menu.
2. Use «Up» or «Down» to select the
Temperature unit line.
6 . 1 b a r
0 8 : 1 5 A M
8 0 ° C
Header
5.1 General
Menu
Time format
hh:mm:ssAM/PM
·········
Pressure unit
bar
Unit of pressure
Temperature unit
°C
Unit of temperature
·········
Display lighting
3. Press «Enter».
The display for the set unit flashes.
4. Use «Up» or «Down» to set the unit.
5. Press «Enter».
The setting is applied.
6. Press «Escape» repeatedly to leave this menu.
8.2.11 Setting the display illumination
Set the display lighting mode:
Mode
1
2
3
Indication
automatic
on
off
Function
The illumination extin‐
guishes after the
time-
out has elapsed.
Permanent setting
Illumination "on"
Permanent setting
Illumination "off"
Tab. 51 Display illumination
Precondition Access level 2 is activated.
1. Open the 5.1
<Configuration – General> menu.
2. Use «Up» or «Down» to select the
Display lighting line.
8
Initial Start-up
8.2
Setting the controller
No.: 9_9450 12 E
User Manual Controller
SIGMA CONTROL 2 SCREW FLUID ≥5.0.X
69