Machine number
Start time [sec]
Delay time [sec]
16
Tab. 64 Auto start delay time
Precondition Access level 2 is activated.
1. Open the 5.4
Compressor start menu.
2. Use the «Up» or «Down» keys to select the
Target line.
6 . 1 b a r
0 8 : 1 5 A M
8 0 ° C
Header
5.4 Compressor start
Menu
▶1 Compressor on
Active line
▶2 Compressor off
·········
Autostart:
☑
Auto start activated
Target
10s ¦
Actual
0s
Set/expiring delay time
·········
3. Press «Enter».
The
Target display flashes.
4. Use «Up» or «Down» to set the time delay in seconds.
6 . 1 b a r
0 8 : 1 5 A M
8 0 ° C
Header
5.4 Compressor start
Menu
▶1 Compressor on
Active line
▶2 Compressor off
·········
Autostart:
☑
Auto start activated
Target
12s ¦
Actual
0s
·········
5. Press «Enter».
The setting is applied.
6. Press «Escape» repeatedly to leave this menu.
Result The delay time for an auto start after a power failure has been adjusted from 10 s to 12 s.
8
Initial Start-up
8.6
Machine start and machine stop
104
User Manual Controller
SIGMA CONTROL 2 SCREW FLUID ≥5.0.X
No.: 9_9450 12 E