8.6.5 “Venting" function
Prior to the machine's transition from the operating points LOAD to READY you can also activate
an IDLE phase (not with SXC) ("Venting" function). The duration of the IDLING phase can be timed
and/or regulated by internal pressure. The machine-dependent venting phase between the LOAD
and READY operating modes ensures load changes at minimum material stresses and is therefore
activated at the factory (default setting). If this function is not required, you can deactivate it.
Precondition Access level 2 is activated.
1. Open the 5.4.2
<Configuration – Compressor start – Compressor off> menu.
2. Use «Up» or «Down» to select the
Start line.
6 . 1 b a r
0 8 : 1 5 A M
8 0 ° C
Header
5.4.2 Compressor off
Menu
Venting period :
☑
Factory setting: "Venting" function activated
·········
Holidays
:
☐
Start
:
01/01/21
00:00AM
End
:
01/01/21
3. Press «Enter».
The check box
Venting period will flash.
4. Press «UP».
The check box is deactivated.
6 . 1 b a r
0 8 : 1 5 A M
8 0 ° C
Header
5.4.2 Compressor off
Menu
Venting period :
☐
Active line with deactivated check box
·········
Holidays
:
☐
Start
:
01/01/21
00:00AM
End
:
01/01/21
5. Press «Enter».
The setting is applied.
Apart from the discontinuation of the pressure or load requirement, venting of the machine is also
executed when the «OFF» key is pressed.
Press the «OFF» key twice to immediately shut the machine off.
➤ Press the «OFF» key twice.
Result The machine is switched off without venting (IDLE phase).
8.6.6 "Auto start" function
To avoid overloading the mains power supply through several machines starting simultaneously a
delay period determining the auto start of each machine can be entered.
The
Autostart: function is activated (default setting).
8
Initial Start-up
8.6
Machine start and machine stop
102
User Manual Controller
SIGMA CONTROL 2 SCREW FLUID ≥5.0.X