Programming
••••
11
1
Change to the correct type of fixture by pressing Group,
selecting the appropriate fixture type (eg Dsk Chan)
from the toolbar.
2
Type
1 Thru 24
to select the 24 desk channels.
3
Type @ 1 ENTER to patch the 24 desk channels
consecutively from channels 1 through 24 on DMX
output 1.
4
Repeat for each fixture type.
While the Patch window is open the
@
key means “patch at address,” rather than the normal “set at
intensity.”
Patching multiple times
Fixtures can also be patched to multiple locations. For example, selecting Trackspots and typing
1 @ 200
ENTER
will patch Trackspot 1 to DMX channel 200 of the current output, in addition to its first patch
location. Or,
2 @ 290 @ 300 @ 320 ENTER
will patch Trackspot 2 to addresses 290, 300 and 320.
Patching to a different output (HOG 1000 Only)
Any fixture can be patched anywhere on either of the two outputs. Every time you use the
@
key, it will
patch onto the current output, indicated by the highlighted
1 DMX Output
or
2 DMX Output
. To
select the other output, press the
Output>
button on the toolbar and continue patching.
Please note that whilst you can patch to both DMX outputs on an HOG 500, only output 1
connects to the DMX port on the back of the console. The ability to patch fixtures to both
outputs allows shows to be used on both an HOG 500 and an HOG 1000.
Patching Split Fixtures like VL5s
Let’s proceed by patching the VL5s onto Output 1 at DMX address 40 for the intensity and address 320 for
the remaining parameters.
VL5s differ from most other fixtures in that they must be patched twice: once for intensity and once for the
other parameters. Press
Fixt Part...
to toggle between the two. The command line on the display will
display either Patch
VL5 m3 Intensity...:
or
Patch VL5 m3 Pan...:
when the fixture
number is entered.
To patch the VL5s:
1
Press
Group
, and then select
VL5 m3
using the toolbar
and
ENTER
2
Type
1 Thru 6
@ 40
ENTER
on the keypad. This patches the
VL5 intensities to channels 40 through 45.
3
Press
Fixt Part
to select the other parameters for patching.
4
Type
1 Thru 6
@ 320
ENTER
on the keypad to patch the rest of
the parameters.
Different Patch Views
The patch window now shows where the VL5s are patched. To see the patch in more detail, press the
View
button on the patch tool bar. This displays a choice of views allowing some or all of the parameters, not just
the first one for each fixture. Move up and down the patch list by using the up and down arrow buttons and
press
ENTER
to select.
It’s also possible to view the patch display on the external monitor. Hold the
Monitor
button and press
Patch
on the toolbar. Move up and down the external display by selecting the external monitor (press the
Monitor
button to illuminate the LED within, pressing it a second time will bring control back to the main
LCD window) and use the Page Up and Page down keys to scroll the screen.
Now patch the rest of the fixtures:
Patch the Trackspots @49.
Patch the Cyber m2 lithos @ 190.
Patch the Mac 500s @ 100.
Patch the VL6 m3s @ 400.
Содержание HOG 1000
Страница 1: ...Software Version 3 20...
Страница 12: ...6 HOG Version 3 20 This Page intentionally Left Blank...
Страница 22: ...16 HOG Version 3 20 This Page intentionally Left Blank...
Страница 50: ...44 HOG Version 3 20 This Page intentionally Left Blank...
Страница 62: ...56 HOG Version 3 20 This Page intentionally Left Blank...
Страница 74: ...68 HOG Version 3 20 This Page intentionally Left Blank...
Страница 90: ...84 HOG Version 3 20 This Page intentionally Left Blank...
Страница 94: ...88 HOG Version 3 20 This Page intentionally Left Blank...
Страница 119: ...Fixture Library 113...
Страница 123: ...Hardware Notes 117 This Page intentionally Left Blank...