Goodrive300-19 series open loop vector inverter special for hosit Function parameters
-95-
Function
code
Name
Detailed instruction of parameters
Default
value
Modify
voltage
380V
500V
660
range
685~750
V
860~950V
1080~11
80V
690V
voltage:
1120.0V
P08.39
Cooling fan
running
mode
0: Normal mode
1: The fan keeps running after power on
0
○
P08.40
PWM
selection
0x00~0x21
LED ones: PWM mode selection
0: PWM mode 1, three-phase modulation and
two-phase modulation
1: PWM mode 2, three-phase modulation
LED tens: low-speed carrier frequency limit mode
0: Low-speed carrier frequency limit mode 1, the
carrier frequency will limit to 2k if it exceeds 2k at low
speed
1: Low-speed carrier frequency limit mode 2, the
carrier frequency will limit to 4k if it exceeds 4k at low
speed
2: No limit
01
◎
P08.41
Over
commission
selection
0x00~0x11
LED ones
0: Invalid
1: Valid
LED tens (for factory commissioning)
0: Light overcommission; in zone 1
1: Heavy overcommission; in zone 2
00~11
01
P08.42
Keypad
data control
0x000~0x1223
LED ones: frequency enable selection
0: Both
∧
/
∨
key and digital potentiometer
adjustment are valid
1: Only
∧
/
∨
key adjustment is valid
2: Only digital potentiometer adjustment is valid
3: Neither
∧
/
∨
key nor digital potentiometer
0x0000
○
Содержание Goodrive GD300-19-004G-4
Страница 1: ...Series Open Loop Vector Inverter Special for Hoist Goodrive300 19 GD300 19 5R5G 4...
Страница 33: ...Goodrive300 19 series open loop vector inverter special for hosit Installation guidelines 32...
Страница 129: ...Goodrive300 19 series open loop vector inverter special for hosit Basic operation instruction 128...
Страница 135: ...Goodrive300 19 series open loop vector inverter special for hosit Basic operation instruction 134...
Страница 255: ...201610 V2 0 66001 00230 I I...