![INVT Goodrive GD300-19-004G-4 Скачать руководство пользователя страница 114](http://html1.mh-extra.com/html/invt/goodrive-gd300-19-004g-4/goodrive-gd300-19-004g-4_operation-manual_2085749114.webp)
Goodrive300-19 series open loop vector inverter special for hosit Function parameters
-113-
Function
code
Name
Detailed instruction of parameters
Default
value
Modify
switching-off and switching-on signals.
P19.06
Hierarchical
multi-step
speed
reference 0
Hierarchical multi-step speed reference is specially
designed according to the application modes of hoists
(hierarchical joystick/hierarchical remote control).
Goodrive300-19 inverters can set 6 steps speed,
which can be selected by the combination of
hierarchical reference terminals 1~5 (set by S
terminal function, the corresponding function codes
are P05.01~P05.09), corresponding to the speed 0 to
speed 5.
The relations between terminal 1, terminal 2, terminal
3, terminal 4, terminal 5 and hierarchical multi-step
speed are:
Hierarchical
reference terminal 1
OFF ON ON ON ON ON
Hierarchical
reference terminal 2
OFF
OFF
ON ON ON ON
Hierarchical
reference terminal 3
OFF
OFF
OFF
ON ON ON
Hierarchical
reference terminal 4
OFF
OFF
OFF
OFF
ON ON
Hierarchical
reference terminal 5
OFF
OFF
OFF
OFF
OFF
ON
Hierarchical
multi-step speed
0
1
2
3
4
5
Note: Only when all lower hierarchical references
close can the upper hierarchical references close.
Generally, set hierarchical multi-step speed
reference 0 to 0.0% when using hierarchical
terminal reference.
Setting range: 0.0~100.0%
0.0%
○
P19.07
Hierarchical
multi-step
speed
reference 1
0.0%
○
P19.08
Hierarchical
multi-step
speed
reference 2
0.0%
○
P19.09
Hierarchical
multi-step
speed
reference 3
0.0%
○
P19.10
Hierarchical
multi-step
speed
reference 4
0.0%
○
P19.11
Hierarchical
multi-step
speed
reference 5
0.0%
○
P19.12
FWD
switching-off
frequency
The three parameters are switching-off conditions in
forward rotation. The inverter will send switching-off
signal
after
the
running
frequency
exceeds
switching-off frequency and torque verification
2.00Hz
◎
P19.13
FWD
0.0%
◎
Содержание Goodrive GD300-19-004G-4
Страница 1: ...Series Open Loop Vector Inverter Special for Hoist Goodrive300 19 GD300 19 5R5G 4...
Страница 33: ...Goodrive300 19 series open loop vector inverter special for hosit Installation guidelines 32...
Страница 129: ...Goodrive300 19 series open loop vector inverter special for hosit Basic operation instruction 128...
Страница 135: ...Goodrive300 19 series open loop vector inverter special for hosit Basic operation instruction 134...
Страница 255: ...201610 V2 0 66001 00230 I I...