Goodrive300-19 series open loop vector inverter special for hosit Basic operation instruction
-171-
Set value
Function
Instruction
switching-on frequency at stopping.
Note: The functions 35 and 36 are mainly for:
when the brake adopts external control mode,
inform the control system of switching on/off.
37
Motor 2 in operation
After receiving the command of shifting the motor,
send a feedback signal to the upper computer.
Relative parameters list:
Function
code
Name
Detailed instruction of parameters
Default
value
P06.00
HDO output
0: Open collector high-speed pulse output
1: Open collector output
0
P06.01
Y output
0: Invalid
1: In operation
2: Forward rotation operation
3: Reverse rotation operation
4: Jogging operation
5: Inverter fault
6: Frequency degree test FDT1
7: Frequency degree test FDT2
8: Frequency arrival
9: Zero speed running
10: Upper limit frequency arrival
11: Lower limit frequency arrival
12: Ready for operation
13: Pre-magnetizing
14: Overload pre-alarm
15: Underload pre-alarm
16~21: Reserved
22: Running time arrival
23: Modbus communication virtual terminals output
24~32: Reserved
33: Contactor control
34: Brake control
35: Ready for switching off
0
P06.02
HDO output
0
P06.03
Relay RO1
output
1
P06.04
Relay RO2
output
5
Содержание Goodrive GD300-19-004G-4
Страница 1: ...Series Open Loop Vector Inverter Special for Hoist Goodrive300 19 GD300 19 5R5G 4...
Страница 33: ...Goodrive300 19 series open loop vector inverter special for hosit Installation guidelines 32...
Страница 129: ...Goodrive300 19 series open loop vector inverter special for hosit Basic operation instruction 128...
Страница 135: ...Goodrive300 19 series open loop vector inverter special for hosit Basic operation instruction 134...
Страница 255: ...201610 V2 0 66001 00230 I I...