Goodrive300-19 series open loop vector inverter special for hosit Function parameters
-70-
Function
code
Name
Detailed instruction of parameters
Default
value
Modify
increasing
time
accelerates from the minimum output voltage to the
maximum output voltage.
Voltage decreasing time is the time when the inverter
decelerates from the maximum output voltage to the
minimum output voltage.
The setting range: 0.0~3600.0s
P04.30
Voltage
decreasing
time
5.0s
○
P04.31
Maximum
output
voltage
Set the upper and low limit of the output voltage.
The setting range of P04.31: P04.32~100.0% (the
rated voltage of the motor)
The setting range of P04.32: 0.0%~P04.31
100.0%
◎
P04.32
Minimum
output
voltage
0.0%
◎
P04.33
Weakening
coefficient in
constant
power zone
The function is used to adjust the output voltage of
inverter in SVPWM mode in weak magnetic.
Note: Invalid in constant-torque mode
The setting range of P04.33: 1.00~1.30
1.00
○
P05 Group Input terminals
P05.00
HDI input
selection
0: High-speed pulse input. See P05.49~P05.54
1: Digital input. See P05.09
0
◎
P05.01
S1 terminal
function
selection
0: No function
1: Forward rotation operation
2: Reverse rotation operation
3: 3-wire control operation (SIn)
4: Forward jogging
1
◎
P05.02
S2 terminal
function
2
◎
Содержание Goodrive GD300-19-004G-4
Страница 1: ...Series Open Loop Vector Inverter Special for Hoist Goodrive300 19 GD300 19 5R5G 4...
Страница 33: ...Goodrive300 19 series open loop vector inverter special for hosit Installation guidelines 32...
Страница 129: ...Goodrive300 19 series open loop vector inverter special for hosit Basic operation instruction 128...
Страница 135: ...Goodrive300 19 series open loop vector inverter special for hosit Basic operation instruction 134...
Страница 255: ...201610 V2 0 66001 00230 I I...