Goodrive300-19 series open loop vector inverter special for hosit Function parameters
-105-
Function
code
Name
Detailed instruction of parameters
Default
value
Modify
motor 2
impact on control performance.
Note: Users cannot modify
the parameters freely.
P12.08
Leakage
inductance of
asynchronous
motor 2
0.1~6553.5mH
Depend
on
model
○
P12.09
Mutual
inductance of
asynchronous
motor 2
0.1~6553.5mH
Depend
on
model
○
P12.10
Non-load
current of
asynchronous
motor 2
0.1~6553.5A
Depend
on
model
○
P12.11
Magnetic
saturation
coefficient 1
for the iron
core of AM2
0.0~100.0%
80.0%
◎
P12.12
Magnetic
saturation
coefficient 2
for the iron
core of AM2
0.0~100.0%
68.0%
◎
P12.13
Magnetic
saturation
coefficient 3
for the iron
core of AM2
0.0~100.0%
57.0%
◎
P12.14
Magnetic
saturation
coefficient 4
for the iron
core of AM2
0.0~100.0%
40.0%
◎
Содержание Goodrive GD300-19-004G-4
Страница 1: ...Series Open Loop Vector Inverter Special for Hoist Goodrive300 19 GD300 19 5R5G 4...
Страница 33: ...Goodrive300 19 series open loop vector inverter special for hosit Installation guidelines 32...
Страница 129: ...Goodrive300 19 series open loop vector inverter special for hosit Basic operation instruction 128...
Страница 135: ...Goodrive300 19 series open loop vector inverter special for hosit Basic operation instruction 134...
Страница 255: ...201610 V2 0 66001 00230 I I...