Goodrive300-19 series open loop vector inverter special for hosit Function parameters
-76-
Function
code
Name
Detailed instruction of parameters
Default
value
Modify
P05.34
Upper limit of
AI1
corresponding voltage of 0~20mA is 0~10V.
In different cases, the corresponding rated value of
100.0% is different. See the application for detailed
information.
The figure below illustrates different applications:
Input filter time: This parameter is used to adjust the
sensitivity of the analog input. Increasing the value
properly can enhance the anti-interference of the
analog, but weaken the sensitivity of the analog input.
Note: Analog AI1 and AI2 can support 0~10V or
0~20mA input. When AI1 and AI2 selects 0~20mA
input, the corresponding voltage of 20mA is 10V.
AI3 can support -10V~+10V output.
The setting range of P05.32: 0.00V~P05.34
The setting range of P05.33: -100.0%~100.0%
The setting range of P05.34: P05.32~10.00V
The setting range of P05.35: -100.0%~100.0%
The setting range of P05.36: 0.000s~10.000s
The setting range of P05.37: 0.00V~P05.39
The setting range of P05.38: -100.0%~100.0%
The setting range of P05.39: P05.37~10.00V
The setting range of P05.40: -100.0%~100.0%
The setting range of P05.41: 0.000s~10.000s
The setting range of P05.42: -10.00V~P05.44
The setting range of P05.43: -100.0%~100.0%
10.00V
○
P05.35
Correspondin
g setting of
the upper
limit of AI1
100.0%
○
P05.36
AI1 input filter
time
0.100s
○
P05.37
Lower limit of
AI2
0.00V
○
P05.38
Correspondin
g setting of
the lower limit
of AI2
0.0%
○
P05.39
Upper limit of
AI2
10.00V
○
P05.40
Correspondin
g setting of
the upper
limit of AI2
100.0%
○
P05.41
AI2 input filter
time
0.100s
○
P05.42
Lower limit of
AI3
-10.00V
○
P05.43
Correspondin
g setting of
the lower limit
of AI3
-100.0%
○
P05.44
Middle value
of AI3
0.00V
○
P05.45
Correspondin
g middle
setting of
0.0%
○
Содержание Goodrive GD300-19-004G-4
Страница 1: ...Series Open Loop Vector Inverter Special for Hoist Goodrive300 19 GD300 19 5R5G 4...
Страница 33: ...Goodrive300 19 series open loop vector inverter special for hosit Installation guidelines 32...
Страница 129: ...Goodrive300 19 series open loop vector inverter special for hosit Basic operation instruction 128...
Страница 135: ...Goodrive300 19 series open loop vector inverter special for hosit Basic operation instruction 134...
Страница 255: ...201610 V2 0 66001 00230 I I...