Goodrive300-19 series open loop vector inverter special for hosit Basic operation instruction
-168-
delay of S8
terminal
P05.29
Switch-off
delay of S8
terminal
0.000~50.000s
0.000s
P05.30
Switch-on
delay of HDI
terminal
0.000~50.000s
0.000s
P05.31
Switch-off
delay of HDI
terminal
0.000~50.000s
0.000s
P07.37
Bus voltage at
current fault
0.0V
P17.12
Digital input
terminals state
0
7.12 Digital output
Goodrive300-19 series inverters have 2 relay output terminals, 1 open collector Y output terminal and
1 high-speed pulse output terminal in the standard configuration. All functions of the digital input
terminals are programmable by the function codes. The high-speed pulse output terminal HDO can
be selected into high-speed pulse output terminal or switch output terminal by function code.
0
Invalid
14
Overload pre-alarm
1
In operation
15
Underload pre-alarm
2
Forward rotation
operation
16~21
Reserved
3
Reverse rotation
operation
22
Running time arrival