![INVT Goodrive GD300-19-004G-4 Скачать руководство пользователя страница 165](http://html1.mh-extra.com/html/invt/goodrive-gd300-19-004g-4/goodrive-gd300-19-004g-4_operation-manual_2085749165.webp)
Goodrive300-19 series open loop vector inverter special for hosit Basic operation instruction
-164-
Set
value
Function
Instruction
57
Inverter enabling
When a multi-function input terminal is set to 57, the
inverter will not run until the enabling signal becomes
valid, otherwise the inverter will not respond to the
running command. If the function is not selected, the
inverter enabling will be valid by default.
58
Contactor feedback signal
P19.01 selects the contactor is controlled by the
inverter. When the terminal function is set to 58, if the
contactor feedback signal is wrong, the inverter will
alarm contactor feedback fault (TbE).
59
Brake feedback signal
P19.01 selects the brake is controlled by the inverter.
When the terminal function is set to 59, if the brake
feedback signal is wrong, the inverter will alarm brake
feedback fault (FAE).
60
Joystick zero position signal
After the inverter stops, to avoid restart of the inverter,
make sure the joystick returns to zero position (neutral
position). The inverter can restart only when the
joystick returns to zero position and the time is larger
than P19.28.
Note: Signals at zero position are valid only under
joystick mode and hierarchical joystick mode.
61
Hierarchical reference
terminal 1
6 stages setting can be realized by the combination
between the 1
st
level speed contact given by the
direction command and the states of 5 terminals.
Note: Only when all lower hierarchical contacts
close can the upper hierarchical contacts close. If
the lower hierarchical contacts open while the
upper hierarchical contacts close, alarm the
multi-step speed hierarchical reference fault.
62
Hierarchical reference
terminal 2
63
Hierarchical reference
terminal 3
64
Hierarchical reference
terminal 4
65
Hierarchical reference
terminal 5
Содержание Goodrive GD300-19-004G-4
Страница 1: ...Series Open Loop Vector Inverter Special for Hoist Goodrive300 19 GD300 19 5R5G 4...
Страница 33: ...Goodrive300 19 series open loop vector inverter special for hosit Installation guidelines 32...
Страница 129: ...Goodrive300 19 series open loop vector inverter special for hosit Basic operation instruction 128...
Страница 135: ...Goodrive300 19 series open loop vector inverter special for hosit Basic operation instruction 134...
Страница 255: ...201610 V2 0 66001 00230 I I...